Technical illustration
Illustration: Wiring Diagram for GV2ME--
English
2024-05-15
(Select your file)
GV2ME--TI-WD.jpg (239 KB)
GV2ME--TI-WD.png (59 KB)
GV2ME--TI-WD.svg (5 KB)
GV2ME--TI-WD_64x64.gif (1 KB)
GV2ME--TI-WD_369x369.jpg (12 KB)
GV2ME--TI-WD_1500x1500.jpg (96 KB)
GV2ME--TI-WD_4000x4000.png (361 KB)
Select all
Illustration: Wiring Diagram for GV2ME-- : .jpg Illustration: Wiring Diagram for GV2ME-- : .png Illustration: Wiring Diagram for GV2ME-- : .svg Illustration: Wiring Diagram for GV2ME-- : .gif Illustration: Wiring Diagram for GV2ME-- : .jpg Illustration: Wiring Diagram for GV2ME-- : .jpg Illustration: Wiring Diagram for GV2ME-- : .png
User guide
TeSys Power - Deca Motor Circuit Breakers Frame 2 - Use in Explosive Atmospheres
English, French
2024-05-15
(Select your file)
1672546-08.pdf (1697 KB)
TeSys Power - Deca Motor Circuit Breakers Frame 2 - Use in Explosive Atmospheres : .pdf
Data Bulletin
Motor Control Solutions for the North American Market Data Bulletin
English
2024-05-15
Motor Control Solutions for the North American Market Data Bulletin Schneider Electric offers a wide range of solutions to meet your motor control and protection needs. This data bulletin contains information regarding the application of those solutions in the United States and Canada. Topics include wiring diagrams, combination starter construction types, motor starter line diagrams, Short Circuit Current Rating (SCCR) for components, selection tables, and circuit breaker catalog numbering systems.
(Select your file)
8536DB0901.pdf (1115 KB)
Motor Control Solutions for the North American Market Data Bulletin : .pdf
Circularity Profile
Motor circuit breaker,TeSys Deca,push-button
English
2024-05-15
(Select your file)
EoLI_ENVEOLI121004EN_V5.pdf (270 KB)
Motor circuit breaker,TeSys Deca,push-button : .pdf
Environmental disclosure
Motor circuit breaker,TeSys Deca,push-button
English
2024-05-15
(Select your file)
Internal PEP ENVPEP121004EN_V5.pdf (310 KB)
Motor circuit breaker,TeSys Deca,push-button : .pdf
Declaration of conformity
CCC Self-declaration_TeSys GV2ME&GV2P&GV2L_Thailand
SILENT
2024-05-15
(Select your file)
GV2-Bangpoo_CCC-SDoc_2020980307004483.pdf (2615 KB)
CCC Self-declaration_TeSys GV2ME&GV2P&GV2L_Thailand : .pdf
CCC Self-declaration_TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE_France
SILENT
2024-05-15
(Select your file)
GV2-Dijon_CCC-SDoc_2020980307004793.pdf (3594 KB)
CCC Self-declaration_TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE_France : .pdf
DoC
Russian
2024-05-15
(Select your file)
ЕАЭС KZ 7500651.13.12.08916_22.pdf (854 KB)
DoC : .pdf
EU Declaration TeSys GV2ME & GV2P with ATEX
SILENT
2024-05-15
(Select your file)
EU_DoC_GV2ME_GV2P with ATEX_SC16031601E.pdf (492 KB)
EU Declaration TeSys GV2ME & GV2P with ATEX : .pdf
EU Declaration TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE
SILENT
2024-05-15
(Select your file)
PP_EU_Doc_SC16041104H_GV2ME_GV2RT_GV2P_GV2L_GV2LE.docx.pdf (533 KB)
EU Declaration TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE : .pdf
Technical Drawing
Manual StarterAnd Protector 010-32A 3P Technical drawings
English
2024-05-15
(Select your file)
GV2M-0-OD.dwg (275 KB)
GV2M-0-OD.pdf (49 KB)
Select all
Manual StarterAnd Protector 010-32A 3P Technical drawings : .dwg Manual StarterAnd Protector 010-32A 3P Technical drawings : .pdf
motor circuit breaker 25 A Dimensions
SILENT
2024-05-15
(Select your file)
A-GV2ME01-to-ME32_CAD2D-MECHANICAL_FRONT.dwg (53 KB)
A-GV2ME01-to-ME32_CAD2D-MECHANICAL_FRONT.dxf (61 KB)
A-GV2ME01-to-ME32_CAD2D-MECHANICAL_FRONT.pdf (292 KB)
Select all
motor circuit breaker 25 A Dimensions : .dwg motor circuit breaker 25 A Dimensions : .dxf motor circuit breaker 25 A Dimensions : .pdf
Thermal magnetic circuit breaker GV2ME for connection by screw clamp terminals. Dimensions
SILENT
2024-05-15
(Select your file)
gv2meF.dwg (77 KB)
gv2meF.dxf (183 KB)
gv2meF.pdf (318 KB)
Select all
Thermal magnetic circuit breaker GV2ME for connection by screw clamp terminals. Dimensions : .dwg Thermal magnetic circuit breaker GV2ME for connection by screw clamp terminals. Dimensions : .dxf Thermal magnetic circuit breaker GV2ME for connection by screw clamp terminals. Dimensions : .pdf
Thermal magnetic circuit breaker GV2ME for connection by screw clamp terminals. Dimensions
SILENT
2024-05-15
(Select your file)
gv2meR.dwg (33 KB)
gv2meR.dxf (46 KB)
gv2meR.pdf (15 KB)
Select all
Thermal magnetic circuit breaker GV2ME for connection by screw clamp terminals. Dimensions : .dwg Thermal magnetic circuit breaker GV2ME for connection by screw clamp terminals. Dimensions : .dxf Thermal magnetic circuit breaker GV2ME for connection by screw clamp terminals. Dimensions : .pdf
Thermal magnetic circuit-breakers with screw clA terminal Technical drawings
SILENT
2024-05-15
(Select your file)
GV2ME01R.dwg (42 KB)
GV2ME01R.dxf (56 KB)
GV2ME01R.pdf (4 KB)
Select all
Thermal magnetic circuit-breakers with screw clA terminal Technical drawings : .dwg Thermal magnetic circuit-breakers with screw clA terminal Technical drawings : .dxf Thermal magnetic circuit-breakers with screw clA terminal Technical drawings : .pdf
Thermal magnetic circuit-breakers with screw clamp terminal
SILENT
2024-05-15
(Select your file)
GV2ME01F.dxf (51 KB)
GV2ME01F.dwg (40 KB)
Select all
Thermal magnetic circuit-breakers with screw clamp terminal : .DXF Thermal magnetic circuit-breakers with screw clamp terminal : .DWG
Certificate
ATEX Certificate TeSys GV2ME&GV2P
SILENT
2024-05-15
(Select your file)
GV2ME-P_06ATEX0035X.02.pdf (2085 KB)
ATEX Certificate TeSys GV2ME&GV2P : .pdf
RINA Type Approval Certificate_TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE
SILENT
2024-05-15
(Select your file)
RINA_GV2_ELE373320CS.PDF (399 KB)
RINA Type Approval Certificate_TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE : .pdf
Instruction sheet
GV2GA01 - Set of connections
English, French
2024-05-15
(Select your file)
1385421_01A55.pdf (159 KB)
GV2GA01 - Set of connections : .PDF
CAD
TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER - 3D CAD
SILENT
2024-05-15
(Select your file)
MCADPD0003997_3D-simplified.stp (3270 KB)
MCADPD0003997_2D-isometric.dxf (133 KB)
MCADPD0003997_2D-left.dwg (27 KB)
MCADPD0003997_2D-left.dxf (45 KB)
MCADPD0003997_2D-right.dwg (26 KB)
MCADPD0003997_2D-right.dxf (43 KB)
MCADPD0003997_2D-top.dwg (25 KB)
MCADPD0003997_2D-top.dxf (42 KB)
MCADPD0003997_2D-back.dwg (21 KB)
MCADPD0003997_2D-back.dxf (27 KB)
MCADPD0003997_2D-bottom.dwg (22 KB)
MCADPD0003997_2D-bottom.dxf (31 KB)
MCADPD0003997_2D-front.dwg (26 KB)
MCADPD0003997_2D-front.dxf (49 KB)
MCADPD0003997_2D-isometric.dwg (49 KB)
Select all
TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER - 3D CAD : .stp TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER - 3D CAD : .dxf TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER - 3D CAD : .dwg TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER - 3D CAD : .dxf TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER - 3D CAD : .dwg TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER - 3D CAD : .dxf TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER - 3D CAD : .dwg TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER - 3D CAD : .dxf TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER - 3D CAD : .dwg TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER - 3D CAD : .dxf TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER - 3D CAD : .dwg TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER - 3D CAD : .dxf TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER - 3D CAD : .dwg TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER - 3D CAD : .dxf TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER - 3D CAD : .dwg