BK500EI
APC Back-UPS, 500VA/300W, Tower, 230V, 4x IEC C13 Outlets , User Replaceable Battery
|
|
|
Overview
Lead time
|
Usually in Stock
|
Main
Main Input Voltage
|
230 V
|
Main Output Voltage
|
230 V
|
Rated power in W
|
300 W
|
Rated power in VA
|
500 VA
|
Product or component type
|
Uninterruptible power supply (UPS)
|
Input Connection Type
|
IEC 60320 C14
|
Output connection type
|
3 IEC 60320 C13
1 IEC 60320 C13 surge
2 IEC Jumpers surge
|
Number of cables
|
2
|
Battery type
|
Lead-acid battery
|
Provided equipment
|
CD with software
Documentation CD
1 x detachable IEC power cord
1 x detachable 1.2 m IEC power cord
Telephone cable
USB cable
Warranty card
|
Batteries & Runtime
Number of battery filled slots
|
0
|
Number of battery free slots
|
0
|
Battery recharge time
|
8 h
|
Number of battery replacement quantity
|
1
|
Battery voltage
|
12 V
|
Battery capacity
|
7.0 Ah
|
Battery charger power
|
10 W rated
|
Battery power in VAH
|
83 VAh capacity
84 VAh runtime
|
Battery life
|
4…6 year(s)
|
Extended runtime
|
0
|
General
Number of power module free slots
|
0
|
Number of power module filled slots
|
0
|
Redundant
|
No
|
Physical
Colour
|
Beige
|
Height
|
16.5 cm
|
Width
|
9.1 cm
|
Depth
|
28.4 cm
|
Net weight
|
6.32 kg
|
Mounting location
|
Front
|
Mounting preference
|
No preference
|
Mounting mode
|
Not rack-mountable
|
Two post mountable
|
0
|
USB compatible
|
No
|
Input
Network frequency
|
47...63 Hz
50/60 Hz +/- 3 Hz auto-sensing
|
Input voltage limits
|
160...300 V adjustable
180...266 V
|
Maximum input current
|
7 A
|
Switching current capacity
|
7 A
|
Output
Maximum configurable power in W
|
300 W
|
Output frequency
|
47...63 Hz sync to mains
50/60 Hz +/- 1 Hz unsynchronised
|
UPS type
|
Standby
|
Wave type
|
Stepped approximation to a sinewave
|
Maximum configurable power in VA
|
500 VA
|
Transfer time
|
6 ms typical : 10 ms maximum
|
Conformance
Product certifications
|
C-Tick
CE
GOST
VDE
|
Standards
|
EN/IEC 62040-1:2019/A11:2021
EN/IEC 62040-2:2006/AC:2006
EN/IEC 62040-2:2018
|
Environmental
Ambient air temperature for operation
|
0…40 °C
|
Relative humidity
|
0…95 %
|
Operating altitude
|
0...10000 ft
|
Ambient air temperature for storage
|
-15…45 °C
|
Storage Relative Humidity
|
0…95 %
|
Storage altitude
|
0.00…15240.00 m
|
Acoustic level
|
40 dBA
|
Heat dissipation
|
24 Btu/h
|
Communications & Management
Free slots
|
0
|
Control panel
|
LED status display with on line : on battery : replace battery and overload indicators
|
Alarm
|
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
|
Surge Protection and Filtering
Surge energy rate
|
310 J
|
Noise suppression
|
Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449
|
Packing Units
Unit Type of Package 1
|
PCE
|
Number of Units in Package 1
|
1
|
Package 1 Height
|
17.8 cm
|
Package 1 Width
|
24.1 cm
|
Package 1 Length
|
36.8 cm
|
Package 1 Weight
|
7.05 kg
|
Unit Type of Package 2
|
PAL
|
Number of Units in Package 2
|
30
|
Package 2 Height
|
133 cm
|
Package 2 Width
|
100 cm
|
Package 2 Length
|
120 cm
|
Package 2 Weight
|
490 kg
|
SCC14
|
10731304016356
|
Offer Sustainability
Contractual warranty
|
|