Contacts material
|
Cadmium free
|
[Us] rated supply voltage
|
230 V AC 50/60 Hz
|
Voltage range
|
0.85...1.15 Us
|
[In] rated current
|
5 A AC
|
Repeat accuracy
|
+/- 0.5 %
|
Setting accuracy of time delay
|
10 % at full scale at 25 °C conforming to EN/IEC 61812-1
|
Temperature drift
|
0.05 %/°C
|
Maximum reset time
|
250 ms after time delay, on de-energisation
50 ms during time delay, on de-energisation
|
Voltage drift
|
+/- 0.2 %/V
|
Maximum switching capacity
|
4 x 5 A
|
Maximum temporary permissible current
|
10 A for < 10 s
|
Minimum switching current
|
100 mA
|
Electrical durability
|
100000 cycles at 250 V AC resistive
|
Mechanical durability
|
10000000 cycles
|
Maximum power consumption
|
3 VA
|
[Ui] rated insulation voltage
|
250 V conforming to IEC 255 Group C
250 V conforming to VDE 0010
|
Output overvoltage protection
|
2 J
|
Surge withstand
|
2 kV conforming to EN/IEC 61000-4-5 level 3
|
Creepage distance
|
4 kV/3 conforming to IEC 60664-1
|
Local signalling
|
1 LED (red) for output in operation
1 LED (yellow) for power ON
|
Net weight
|
0.05 kg
|
Immunity to microbreaks
|
5 ms
|
Dielectric strength
|
2 kV for 1 mA/1 minute at 50 Hz conforming to EN/IEC 60601-1
2 kV for 1 mA/1 minute at 50 Hz conforming to EN/IEC 61812-1
|
Standards
|
EN 61000-6-2
EN 50081-2
EN/IEC 60601-1
EN/IEC 60601-2
73/23/EEC
93/68/EEC
89/336/EEC
EN/IEC 61812-1
|
Product certifications
|
CUL
UL
|
Ambient air temperature for operation
|
-20…60 °C
|
Ambient air temperature for storage
|
-40…70 °C
|
IP degree of protection
|
IP50 conforming to IEC 60529
|
Vibration resistance
|
0.35 mm (f= 10…55 Hz) conforming to IEC 60068-2-6
|
Relative humidity
|
95 % without condensation conforming to IEC 60068-2-6
|
Resistance to electrostatic discharge
|
6 kV in contact conforming to EN/IEC 61000-4-2 level 3
8 kV in air conforming to EN/IEC 61000-4-2 level 3
|
Resistance to electromagnetic fields
|
10 V/m conforming to EN/IEC 61000-4-3 level 3
|
Resistance to fast transients
|
2 kV conforming to EN/IEC 61000-4-4 level 3
|
Immunity to radioelectric fields
|
10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6 level 3
|
Immunity to voltage dips
|
>= 95 % / 1 s conforming to EN/IEC 61000-4-11
30 % / 10 ms conforming to EN/IEC 61000-4-11
60 % / 100 ms conforming to EN/IEC 61000-4-11
|
Disturbance radiated/conducted
|
Class B conforming to EN 55022 (EN 55011 group 1)
|