Contacts type and composition
|
1 C/O
|
Contacts material
|
Cadmium free
|
Height
|
3.5 in (90 mm)
|
Depth
|
2.8 in (72 mm)
|
Control type
|
Selector switch front panel
|
[Us] rated supply voltage
|
24...240 V AC 50/60 Hz
24 V DC
|
Voltage range
|
0.85...1.1 Us
|
Supply frequency
|
50...60 Hz +/- 5 %
|
Release of input voltage
|
10 V
|
Connections - terminals
|
Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
|
Tightening torque
|
5.3…8.9 lbf.in (0.6…1 N.m) IEC 60947-1
|
Housing material
|
Self-extinguishing
|
Repeat accuracy
|
+/- 0.5 % IEC 61812-1
|
Temperature Drift
|
+/- 0.05 %/°C
|
Voltage drift
|
+/- 0.2 %/V
|
Setting accuracy of time delay
|
+/- 10 % of full scale 25 °C IEC 61812-1
|
Time delay type
|
Power on-delay - A- Power on-delay relay
On-delay and off-delay - Ac- On-delay and off-delay relay w/ control signal
Power on-delay - At- Power on-delay relay w/ pause/summation (Y1)
Interval - B- Single interval relay w/ control signal
Interval - Bw- Double interval relay w/ control signal
Off-delay - C- Off-delay relay w/ control signal
Symmetrical flashing - D- Symmetrical flashing relay (starting pulse-off)
Symmetrical flashing - Di- Symmetrical flashing relay (starting pulse-on)
Interval - H- Interval relay
Interval - Ht- Interval relay w/ pause/summation (Y1)
|
Control signal pulse width
|
100 ms with load in parallel typical
30 ms typical
|
Insulation resistance
|
100 MOhm 500 V DC IEC 60664-1
|
Reset time
|
120 ms on de-energisation typical
|
On-load factor
|
100 %
|
Power consumption in VA
|
0…32 VA 240 V AC
|
Maximum power consumption in W
|
0.6 W 24 V DC
|
Minimum switching current
|
10 mA 5 V DC
|
Maximum switching current
|
8 A AC/DC
|
Maximum switching voltage
|
250 V AC
|
Breaking capacity
|
2000 VA
|
Operating frequency
|
10 Hz
|
Electrical durability
|
100000 cycles resistive 8 A 250 V AC
|
Mechanical durability
|
10000000 cycles
|
Dielectric strength
|
2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1
|
[Uimp] rated impulse withstand voltage
|
5 kV 1.2/50 µs
|
Power on delay
|
100 ms
|
Marking
|
CE
|
Creepage distance
|
4 kV/3 IEC 60664-1
|
Safety reliability data
|
B10d = 270000
MTTFd = 296.8 years
|
Mounting position
|
Any position in relation to normal vertical mounting plane
|
Mounting support
|
35 mm DIN rail conforming to IEC 60715
|
Local signalling
|
LED indicator on steady: relay energised, no timing in progress
LED indicator 80 % ON and 20 % OFF flashing: timing in progress
LED indicator 5 % ON and 95 % OFF pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L)
|
Function available
|
A- Power on-delay relay-1 C/O
Ac- On-delay and off-delay relay w/ control signal-1 C/O
At- Power on-delay relay w/ pause/summation (Y1)-1 C/O
B- Single interval relay w/ control signal-1 C/O
Bw- Double interval relay w/ control signal-1 C/O
C- Off-delay relay w/ control signal-1 C/O
D- Symmetrical flashing relay (starting pulse-off)-1 C/O
Di- Symmetrical flashing relay (starting pulse-on)-1 C/O
H- Interval relay-1 C/O
Ht- Interval relay w/ pause/summation (Y1)-1 C/O
|
Net Weight
|
0.15 lb(US) (0.07 kg)
|
Control Type
|
Without test button
|
Number of functions
|
10
|
Time delay type
|
A, Ac, At, B, Bw, C, D, Di, H, Ht
|
Functionality
|
Multifunction
|
Compatibility code
|
RE17
|
Immunity to microbreaks
|
20 ms
|
Standards
|
2006/95/EC
2004/108/EC
IEC 61812-1
IEC 61000-6-2
IEC 61000-6-3
IEC 61000-6-4
IEC 61000-6-1
|
Product Certifications
|
CSA
GL
cULus
|
Ambient Air Temperature for Storage
|
-22…140 °F (-30…60 °C)
|
Ambient Air Temperature for Operation
|
-4…140 °F (-20…60 °C)
|
IP degree of protection
|
IP20 IEC 60529 terminal block)
IP40 IEC 60529 housing)
IP50 IEC 60529 front panel)
|
Vibration resistance
|
20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
|
Shock resistance
|
15 gn 11 ms IEC 60068-2-27
|
Relative Humidity
|
93 % without condensation IEC 60068-2-30
|
Electromagnetic compatibility
|
Electrostatic discharge immunity test 6 kV in contact) level 3 IEC 61000-4-2
Electrostatic discharge immunity test 8 kV in air) level 3 IEC 61000-4-2
Susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) level 3 IEC 61000-4-3
Electrical fast transient/burst immunity test 1 kV capacitive connecting clip) level 3 IEC 61000-4-4
Electrical fast transient/burst immunity test 2 kV direct) level 3 IEC 61000-4-4
1.2/50 µs shock waves immunity test 1 kV differential mode) level 3 IEC 61000-4-5
1.2/50 µs shock waves immunity test 2 kV common mode) level 3 IEC 61000-4-5
Conducted RF disturbances 10 V 0.15...80 MHz) level 3 IEC 61000-4-6
Voltage dips and interruptions immunity test 0 % 1 cycle) IEC 61000-4-11
Voltage dips and interruptions immunity test 70 % 25/30 cycles) IEC 61000-4-11
Conducted and radiated emissionsclass B EN 55022
|
Packaging without single use plastic
|
Yes
|
Packaging made with recycled cardboard
|
Yes
|
SCIP Number
|
7bdc2711-0ad2-427c-8ece-532c5e9f09d7
|
California proposition 65
|
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
REACh Regulation
|
REACh Declaration
|
EU RoHS Directive
|
Pro-active compliance (Product out of EU RoHS legal scope)
|
Mercury free
|
Yes
|
Sustainable packaging
|
Yes
|
RoHS exemption information
|
Yes
|
China RoHS Regulation
|
China RoHS declaration
|
Environmental Disclosure
|
Product Environmental Profile
|
Circularity Profile
|
End of Life Information
|
Take-back
|
No
|
Carbon footprint (kg CO2 eq, Total Life cycle)
|
55
|