Contact operation
|
Standard
|
[Uc] control circuit voltage
|
230 V AC 50/60 Hz
|
Status LED
|
Without
|
Control type
|
Without push-button
|
[Uimp] rated impulse withstand voltage
|
2.5 kV during 1.2/50 µs conforming to IEC 61810-7
|
[Ie] rated operational current
|
3 A (AC-1/DC-1) NO conforming to IEC
1.5 A (AC-1/DC-1) NC conforming to IEC
|
Minimum switching capacity
|
25 mW subject to switching frequency, environment or expected reliability level etc
|
Average coil consumption in VA
|
1.2 AC
|
Operating time
|
20 ms between coil de-energisation and making of the Off-delay contact
20 ms between coil energisation and making of the On-delay contact
|
CAD overall width
|
21 mm
|
CAD overall height
|
27 mm
|
CAD overall depth
|
46 mm
|
Minimum switching current
|
5 mA subject to switching frequency, environment or expected reliability level etc
|
Minimum switching voltage
|
5 V subject to switching frequency, environment or expected reliability level etc
|
Rated operational voltage limits
|
184...253 V AC
|
[Ui] rated insulation voltage
|
250 V conforming to IEC
|
Maximum switching voltage
|
250 V AC
28 V DC
|
Drop-out voltage threshold
|
>= 0.15 Uc AC
|
Load current
|
3 A at 250 V AC
3 A at 28 V DC
|
Maximum switching capacity
|
750 VA AC
84 W DC
|
Average resistance
|
16500 Ohm at 23 °C +/- 15 %
|
Mechanical durability
|
10000000 cycles
|
Electrical durability
|
100000 cycles for resistive load
|
Safety reliability data
|
B10d = 100000
|
Operating rate
|
<= 1200 cycles/hour under load
<= 18000 cycles/hour no-load
|
Utilisation coefficient
|
20 %
|
Dielectric strength
|
2000 V AC between coil and contact with basic insulation
2000 V AC between poles with basic insulation
1000 V AC between contacts with micro disconnection
|
Protection category
|
RT I
|
Pollution degree
|
2
|
Operating position
|
Any position
|
Test levels
|
Level A group mounting
|
Sale per indivisible quantity
|
10
|
Contacts material
|
Silver alloy (Ag/Ni)
|
Net weight
|
0.032 kg
|