Standards
|
IEC 61131-2:2007
UL 508
|
Electromagnetic compatibility
|
Emission standard for industrial environments conforming to IEC 61000-6-4 2011/A1
Immunity for industrial environments conforming to IEC 61000-6-2
|
Product certifications
|
UL 508
CSA 22-2 No 142-M1987
CSA 22-2 No 213-M1987
|
Ambient air temperature for operation
|
-20…60 °C (horizontal position)
-20…50 °C (vertical position)
|
Ambient air temperature for storage
|
-40…85 °C
|
Relative humidity
|
5…95 % non-condensing
|
IP degree of protection
|
IP20
|
Pollution degree
|
2 conforming to IEC 60664
|
Environmental characteristic
|
No corrosion resistance
|
Operating altitude
|
0...2000 m
|
Storage altitude
|
0…3000 m
|
Vibration resistance
|
3.5 mm constant amplitude at 5…84 Hz on 35 x 15 mm symmetrical DIN rail
9.8 m/s² constant acceleration at 8.4…150 Hz
|
Shock resistance
|
147 m/s² for 11 ms
|
Resistance to electrostatic discharge
|
4 kV contact discharge conforming to IEC 61000-4-2
8 kV air discharge conforming to IEC 61000-4-2
|
Resistance to electromagnetic fields
|
1 V/m 2...2.7 GHz conforming to IEC 61000-4-3
10 V/m 80 MHz...2 GHz conforming to IEC 61000-4-3
|
Resistance to fast transients
|
1 kV (I/O) conforming to IEC 61000-4-4
1 kV (shielded cable) conforming to IEC 61000-4-4
2 kV (power lines) conforming to IEC 61000-4-4
|
Surge withstand
|
0.5 kV in differential mode 24 V DC conforming to IEC 61000-4-5
1 kV in common mode 24 V DC conforming to IEC 61000-4-5
1 kV in differential mode 230 V AC conforming to IEC 61000-4-5
2 kV in common mode 230 V AC conforming to IEC 61000-4-5
|
Disturbance radiated/conducted
|
10 V 0.15...80 MHz conforming to IEC 61000-4-6
|