Schneider-Electric
 
TPRVM001 picture- scope
TPRVM001
Voltage interface module, TeSys island, 690VAC 47-63 Hz, Isolated switching input for safe stop
Schneider Electric
Characteristics
Main
Range TeSys
Product name TeSys island
Device short name TPRVM
Product or component type Voltage interface module
Device presentation Monitoring of the mains voltage powering the island
Reporting of the voltage to the bus coupler to enable power & energy monitoring
Function of module Monitoring of voltages in single phase systems L-N or L-L
Monitoring of voltages in 3-phase systems without neutral N connection
Calculation of RMS phase voltages, voltage phase sequence, fundamental frequency
Identification of dip and swell events level and duration
Product compatibility TPRBC bus coupler
[Ue] rated operational voltage 690 V AC 47...63 Hz
[Ui] rated insulation voltage 690 V conforming to IEC 61010-1
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 61010-1
Overvoltage category III
Monitoring type Phase voltage 100...690 V
Phase frequency 47...63 Hz
Phase sequence
Measurement accuracy Voltage: +/- 5 %,
Frequency: +/- 1 Hz,
Local signalling 1 LED (green/red) for DS (device status)
1 LED (green/red) for VS (voltage status)
Complementary
[Us] rated supply voltage 24 V DC supplied by the bus coupler
Current consumption 2 mA
Power dissipation in W 0.5 W maximum
Standards IEC 61010-2-201
UL 61010-2-201
CSA C22.2 No 61010-2-201
Product certifications CSA
UL
EAC (pending)
Mounting mode Horizontal and vertical (35 mm symmetrical rail)
Connections - terminals Measuring input: removable spring terminal block 3 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) rigid
Measuring input: removable spring terminal block 3 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Measuring input: removable spring terminal block 3 cable(s) 0.25…2.5 mm² (AWG 22...AWG 14) flexible with cable end
Width 25 mm
Height 118 mm
Depth 114 mm
Net weight 0.159 kg
Environment
Ambient air temperature for storage -25…70 °C
Ambient air temperature for operation -10…60 °C
Relative humidity 5…95 %
Operating altitude 0...2000 m without derating
IP degree of protection IP20
Pollution degree 2
Protective treatment TC
Fire resistance 960 °C conforming to UL 94
Shock resistance 15 gn (duration = 11 ms) conforming to IEC 60068-2-27
Vibration resistance 1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Electromagnetic compatibility Electrostatic discharge, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF fields, level 3, 10 V/m, conforming to EN/IEC 61000-4-3
Line voltage circuit: fast transients immunity test, level 3, 2 kV, conforming to EN/IEC 61000-4-4
Line voltage circuit: surge immunity test (common mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6.500 cm
Package 1 Width 13.500 cm
Package 1 Length 15.500 cm
Package 1 Weight 233.000 g
Unit Type of Package 2 S03
Number of Units in Package 2 16
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 4.295 kg
Offer Sustainability
Packaging without single use plastic No
Packaging made with recycled cardboard Yes
SCIP Number 6abfba9c-f9d9-4a50-b2bb-a7925a83f0d6
REACh Regulation
print REACh Declaration
EU RoHS Directive Compliant with Exemptions
Mercury free Yes
RoHS exemption information
print Yes
China RoHS Regulation
print China RoHS declaration
Environmental Disclosure
print Product Environmental Profile
Circularity Profile
print End of Life Information
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Halogen content performance Halogen free plastic parts product
California proposition 65 WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Take-back No
Contractual warranty
Warranty 18 months