Device application
|
Building
|
Number of channels
|
1
|
Power consumption in VA
|
6 VA
|
[Ue] rated operational voltage
|
230 V AC +10 % -15 % at 50/60 Hz
|
Maximum switching current
|
10 A - 250 V AC pf = 0.6
16 A - 250 V AC pf = 1
|
Electrical insulation class
|
Class II
|
Opening distance
|
< 3 mm
|
Status LED
|
LED (green) threshold reached
LED (red) brightness less than the threshold
|
Time delay
|
20 s on closing
80 s on breaking contact
|
9 mm pitches
|
2
|
Light intensity adjustment
|
2…100 lux
|
Connections - terminals
|
1 x 6 mm² screw terminals
|
Height
|
83 mm
|
Width
|
18 mm
|
Depth
|
68 mm
|
Net weight
|
173 g
|
Brightness sensing type
|
Analog wall-mounted cell
|
Control type
|
By brightness detection
|
Market segment
|
Small commercial
Residential
|
Compatibility code
|
IC100
|