A9XMSB11
Communication module, EcoStruxure I/O Smart Link, Modbus, RS485
|
|
|
Main
Range of product
|
EcoStruxure
|
Product name
|
EcoStruxure I/O Smart Link
|
Product or component type
|
Smart communication module
|
Device short name
|
I/O Smart Link
|
Application type
|
Load control
Breaker status monitoring
Basic energy metering E
|
Number max of connected devices
|
Up to 11 wired devices
|
Group of channels
|
1 group of 11 digital channels
|
Maximum supply current
|
1.5 A
|
[Us] rated supply voltage
|
24 V DC +/- 20 %
|
Connectivity to devices
|
Digital input and output
Pulse output meter
|
Communication service
|
Modbus server for RS485
|
Web server
|
BMS controller compatible
|
Complementary
Application specific I/O
|
Pulse totalising counter
Pulse converter
|
Protection type
|
Against reverse polarity for auxiliary supply
Against reverse polarity for input
Overvoltage at 33 V DC for digital output
|
Immunity to microbreaks
|
10 ms
|
Reset
|
Factory reset on front face
By booted push-button
By address encoder
By plug in, plug out the power supply
|
Input/output type
|
2 inputs + 1 output per digital channel
|
Input type
|
Current sink for digital input, 24 V DC +/- 20 % at 2.5 mA
|
Maximum permanent current
|
5 mA for digital input
|
Electronic filtering time
|
2 ms for digital input from state 0 to state 1
|
Output type
|
Logic current source: 24 V - DC - 100 mA
|
Maximum voltage drop
|
<1 V at state 1 digital output
|
Inrush current
|
0.5 A for digital output
7 A for power supply
|
Local signalling
|
Communication: 1 LED (yellow)
Status: 1 LED (green, orange and red)
|
Type of setting
|
Modbus address 01...99 for address encoders
Reset for address encoders
Reset for plug in, plug out the auxiliary supply
|
Mounting position
|
Horizontal and vertical on DIN rail
|
Colour
|
White (RAL 9003)
|
Location of connection
|
Front
|
Connections - terminals
|
Spring-loaded terminal Ti24 qty: 11 for digital input/output, ordered separately
Plug-in connector qty: 1 for supply circuit
Plug-in connector qty: 1 for communication bus
|
Clamping connection capacity
|
2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, flexible with cable end for communication bus
2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, flexible without cable end for communication bus
2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, rigid with cable end for communication bus
2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, rigid without cable end for communication bus
1 x 0.2...1 x 1.5 mm², flexible with cable end for control
1 x 0.2...1 x 1.5 mm², flexible without cable end for control
1 x 0.2...1 x 1.5 mm², rigid with cable end for control
1 x 0.2...1 x 1.5 mm², rigid without cable end for control
2 x 0.2...2 x 1.5 mm², flexible with cable end for supply circuit
2 x 0.2...2 x 1.5 mm², flexible without cable end for supply circuit
2 x 0.2...2 x 1.5 mm², rigid with cable end for supply circuit
2 x 0.2...2 x 1.5 mm², rigid without cable end for supply circuit
|
Wire stripping length
|
Control: 10 mm
Supply circuit: 7 mm
Communication bus: 7 mm
|
Communication network type
|
RS485 Modbus RTU client/server SUB-D 9 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
|
9 mm pitches
|
0 useful
|
Height
|
22.5 mm
|
Width
|
359 mm
|
Depth
|
42 mm
|
Net weight
|
188 g
|
Provided equipment
|
Set of 1 bus connector
Set of 1 power supply connector
Set of 2 locking clips
|
Range compatibility
|
Acti 9 iTL auxiliary
Linergy Linergy FM
Acti 9 iOF+SD 24
Acti 9 iACT24
Acti 9 iATL24
PowerLogic pulse output meter
Acti 9 RCA iC60
Acti 9 Acti9 iCT auxiliary
Acti 9 Acti9 iC60
Acti 9 Acti9 iID
Acti 9 Acti9 iSW-NA
Acti 9 Acti9 iDPN Vigi
Acti 9 Acti9 C40
Multi9 Multi9 C60
Acti 9 Acti9 DT40
Acti 9 Acti9 DT60
Acti 9 Acti9 I-NA
Acti 9 Acti9 ITG40
Acti 9 Acti9 iDPN
Acti 9 Acti9 Reflex iC60 Ti24 connector
|
Commissioning interface
|
EcoStruxure Power Commission
|
Market segment
|
Buildings
Small commercial
|
Compatibility code
|
Acti 9 Smartlink
|
Environment
IP degree of protection
|
IP20
|
IK degree of protection
|
IK06 conforming to IEC 62262
|
Pollution degree
|
3
|
Electromagnetic compatibility
|
Resistance to electrostatic discharge (air discharge), class B, 8 kV, conforming to IEC 61000-4-2
Resistance to electrostatic discharge (contact discharge), class B, 4 kV, conforming to IEC 61000-4-2
Resistance to radiated electromagnetic fields (80 MHz...3 GHz), class A, 10 V/m, conforming to IEC 61000-4-3
Power supply: resistance to radiated electromagnetic fields (1.4…6 GHz), class A, 3 V/m, conforming to IEC 61000-4-3
Power supply: resistance to fast transient (5...100 kHz), class B, 2 kV, conforming to IEC 61000-4-4
Input/output: resistance to fast transient, class B, 1 kV, conforming to IEC 61000-4-4
Communication bus: resistance to fast transient (0.15...80 MHz), class B, 1 kV, conforming to IEC 61000-4-4
Conducted EMC (0.15...80 MHz), class A, 3 V, conforming to IEC 61000-4-6
Conducted emission (0.15...30 MHz), class B, conforming to IEC 61326-1
Conducted emission (0.15...30 MHz), class B, conforming to CISPR 11
Radiated emission (30...6000 MHz), class B, conforming to IEC 61326-1
Radiated emission (30...6000 MHz), class B, conforming to CISPR 11
Power supply: surges (DM coupling 42 Ohm), class B, 1 kV, conforming to IEC 61000-4-5
Power supply: surges (CM coupling 42 Ohm), class B, 2 kV, conforming to IEC 61000-4-5
Communication bus: surges (CM coupling 2 Ohm), class B, 1 kV, conforming to IEC 61000-4-5
|
Environmental characteristic
|
Corrosive 3C2 conforming to IEC 60721-3-3
Salt mist 2 conforming to IEC 60068-2-52
|
Vibration resistance
|
1 gn, amplitude = 3.5 mm (f = 5…300 Hz)10 cycles conforming to EN/IEC 60068-2-6
|
Shock resistance
|
15 gn for 11 ms conforming to IEC 60068-2-27
|
Fire resistance
|
Other parts: 650 °C ( 30 s ) conforming to IEC 60695-2-10
On connection terminals: 960 °C ( 30 s ) conforming to IEC 60695-2-10
|
Tropicalisation
|
2
|
Relative humidity
|
0…93 % at 40 °C
|
Operating altitude
|
0...2000 m
|
Ambient air temperature for operation
|
-25…60 °C
|
Ambient air temperature for storage
|
-40…85 °C
|
Standards
|
IEC 61010-2-201
IEC 61010-1
|
Packing Units
Unit Type of Package 1
|
PCE
|
Number of Units in Package 1
|
1
|
Package 1 Height
|
3.300 cm
|
Package 1 Width
|
6.500 cm
|
Package 1 Length
|
37.000 cm
|
Package 1 Weight
|
242.000 g
|
Unit Type of Package 2
|
S03
|
Number of Units in Package 2
|
32
|
Package 2 Height
|
30.000 cm
|
Package 2 Width
|
30.000 cm
|
Package 2 Length
|
40.000 cm
|
Package 2 Weight
|
8.200 kg
|
Offer Sustainability
SCIP Number
|
2c4a7f95-9fbf-4b2e-bc7e-82ceeb851894
|
Packaging without single use plastic
|
No
|
Packaging made with recycled cardboard
|
No
|
REACh Regulation
|
REACh Declaration
|
EU RoHS Directive
|
Pro-active compliance (Product out of EU RoHS legal scope)
|
China RoHS Regulation
|
China RoHS declaration
|
RoHS exemption information
|
Yes
|
Environmental Disclosure
|
Product Environmental Profile
|
Circularity Profile
|
End of Life Information
|
Take-back
|
No
|
Carbon footprint (kg.eq.CO2 per CR, Total Life cycle)
|
35
|
Contractual warranty
|
|