Transmission rate
|
9.6, 19.2 and 38.4 kbauds
|
Mounting support
|
Flange
|
Motor flange size
|
66 mm
|
Number of motor stacks
|
1
|
Centring collar diameter
|
36 mm
|
Number of mounting holes
|
2
|
Mounting holes diameter
|
4.4 mm
|
Feedback type
|
BLDC encoder
|
Shaft end
|
Hole
|
Second shaft
|
Without second shaft end
|
Supply voltage limits
|
18…40 V
|
Current consumption
|
7000 mA peak
5500 mA maximum continuous
|
Associated fuse rating
|
10 A
|
Input/output type
|
4 signals (each be used as input or output)
|
Voltage state 0 guaranteed
|
-3...4.5 V
|
Voltage state 1 guaranteed
|
15...30 V
|
Discrete input current
|
10 mA at 24 V on/STO_A for safety input
3 mA at 24 V on/STO_B for safety input
2 mA at 24 V for 24 V signal interface
|
Discrete output voltage
|
23...25 V
|
Maximum switching current
|
100 mA per output
200 mA total
|
Protection type
|
Safe torque off
Overload of output voltage
Short circuit of the output voltage
|
Maximum supply current
|
0.1 A (power stage disabled)
6.8 A at 24 V
3.8 A at 36 V
|
Nominal output power
|
37 W at 24 V
39 W at 36 V
|
Peak stall torque
|
14.95 N.m at 24 V
20.7 N.m at 36 V
|
Continuous stall torque
|
14 N.m
|
Detent torque
|
16.7 N.m
|
Speed feedback resolution
|
12 points/turn motor
0.26° gearbox output
|
Accuracy error
|
+/- 1 point
|
Maximum torsional backlash
|
1 °
|
Rotor inertia
|
1980 kg.cm²
|
Maximum mechanical speed
|
44 rpm
|
Maximum radial force Fr
|
200 N
|
Maximum axial force Fa
|
80 N
|
Service life in hours
|
9000 h bearing
|
Marking
|
CE
|
Type of cooling
|
Natural convection
|
Net weight
|
2.3 kg
|
Standards
|
IEC 60072-1
EN 61800-3 : 2001-02
IEC 50347
IEC 61800-3, Ed 2
EN 61800-3:2001, second environment
IEC 61800-3
IEC 50178
|
Product certifications
|
TÜV
UL
cUL
|
Ambient air temperature for operation
|
50…65 °C (with power derating of 2 % per °C)
0…50 °C (without derating)
|
Permissible ambient air temperature around the device
|
105 °C power amplifier
110 °C motor
|
Ambient air temperature for storage
|
-25…70 °C
|
Operating altitude
|
<= 1000 m without derating
|
Relative humidity
|
15…85 % without condensation
|
Vibration resistance
|
20 m/s² (f= 10…500 Hz) 10 cycles conforming to IEC 60068-2-6
|
Shock resistance
|
150 m/s² 1000 shocks conforming to IEC 60068-2-29
|
IP degree of protection
|
IP41 shaft bushing: conforming to IEC 60034-5
IP54 total except shaft bushing: conforming to IEC 60034-5
|