LTMR08DBD
Motor controller, TeSys T, Motor Management, DeviceNet, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 24VDC
|
|
|
Main
Range
|
TeSys
|
Product name
|
TeSys T
|
Device short name
|
LTMR
|
Product or component type
|
Motor controller
|
Device application
|
Equipment monitoring and control
|
Measurement current
|
0.4…8 A
|
[Us] rated supply voltage
|
24 V DC
|
Current consumption
|
56...127 mA
|
Supply voltage limits
|
20.4…26.24 V DC
|
Communication port protocol
|
DeviceNet
|
Bus type
|
DeviceNet ISO 1198 interface, addressing 1...64, transmission rate 125...500 kbit/s, terminal block with 4 twisted shielded pairs cable
|
Complementary
[Ui] rated insulation voltage
|
690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508
|
[Uimp] rated impulse withstand voltage
|
6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV communication circuit conforming to EN/IEC 60947-4-1
0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
|
Short-circuit withstand
|
100 kA conforming to EN/IEC 60947-4-1
|
Associated fuse rating
|
4 A gG for output
0.5 A gG for control circuit
|
Protection type
|
Thermal overload protection
Overload
Power factor variation
Reverse polarity protection
Earth-leakage protection
Thermal protection
Overload (long time)
Phase failure
Load fluctuation
Phase unbalance
Locked rotor
|
Network and machine diagnosis type
|
Fault recording
Waiting time after overload tripping
Remaining operating time before overload tripping
Phase fault and earth fault trip counters
Starting current and time
Trip history information
Trip context information
Motor control command recording
Running hours counter/operating time
Event recording
|
Logic input number
|
6
|
Input current
|
7 mA
|
Current state 0 guaranteed
|
Logic input: < 5 V and <= 15 mA for 5 ms
|
Current state 1 guaranteed
|
Logic input: < 15 V and 2...15 mA for 15 ms
|
Maximum output switching frequency
|
2 Hz
|
Load current
|
5 A at 250 V AC for logic output
5 A at 30 V DC for logic output
|
Permissible power
|
480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
|
Maximum operating rate
|
1800 cyc/h
|
Contacts type and composition
|
1 NO + 1 NC fault signal
3 NO
|
Metering type
|
Phase current I1, I2, I3 RMS
Temperature
Earth-fault current
Average current Iavg
Imbalance current
|
Measurement accuracy
|
5...15 % earth fault current internal measurement
1 % voltage (100...830 V)
3 % power factor
5 % earth fault current external measurement
+/- 30 min/year internal clock
0,02 temperature
1 % current
5 % active and reactive power
|
Overvoltage category
|
III
|
Connection pitch
|
5.08 mm
|
Connections - terminals
|
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end
|
Tightening torque
|
Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm
|
Pollution degree
|
3
|
Electromagnetic compatibility
|
Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
|
Width
|
91 mm
|
Height
|
61 mm
|
Depth
|
122.5 mm
|
Net weight
|
0.53 kg
|
Web services
|
Web server
|
Compatibility code
|
LTMR
|
Environment
Standards
|
EN 60947-4-1
CSA C22.2 No 14
UL 508
IACS E10
IEC 60947-4-1
|
Product certifications
|
LROS (Lloyds register of shipping)
DNV
GL
UL
C-Tick
BV
CSA
ATEX
RINA
KERI
CCC
ABS
EAC
RMRoS
NOM
|
Protective treatment
|
12 x 24 hour cycles conforming to EN/IEC 60068-2-30
48 h conforming to EN/IEC 60070-2-11
TH conforming to EN/IEC 60068
|
Fire resistance
|
650 °C conforming to EN/IEC 60695-2-12
960 °C conforming to UL 94
|
Ambient air temperature for operation
|
-20…60 °C
|
Ambient air temperature for storage
|
-40…80 °C
|
Operating altitude
|
<= 2000 m without derating
|
Mechanical robustness
|
Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
|
IP degree of protection
|
IP20
|
Packing Units
Unit Type of Package 1
|
PCE
|
Number of Units in Package 1
|
1
|
Package 1 Height
|
13.5 cm
|
Package 1 Width
|
7.0 cm
|
Package 1 Length
|
10.0 cm
|
Package 1 Weight
|
510.0 g
|
Unit Type of Package 2
|
S02
|
Number of Units in Package 2
|
10
|
Package 2 Height
|
15.0 cm
|
Package 2 Width
|
30.0 cm
|
Package 2 Length
|
40.0 cm
|
Package 2 Weight
|
5.429 kg
|
Offer Sustainability
Contractual warranty
|
|