|
|
|
LTMR27CFM
Motor controller, TeSys T, Motor Management, CANopen, 6 logic inputs, 3 relay logic outputs, 1.35 to 27A, 100 to 240VAC
|
|
|
Main
Range
|
TeSys
|
Product name
|
TeSys T
|
Device short name
|
LTMR
|
Product or component type
|
Motor controller
|
Device application
|
Equipment monitoring and control
|
Measurement current
|
1.35…27 A
|
[Us] rated supply voltage
|
100...240 V AC 50/60 Hz
|
Current consumption
|
8...62.8 mA
|
Supply voltage limits
|
93.5…264 V AC
|
Communication port protocol
|
CANopen
|
Bus type
|
CANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit/s, SUB-D 9 with 4 twisted shielded pairs cable
CANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit/s, terminal block with 4 twisted shielded pairs cable
|
Complementary
[Ui] rated insulation voltage
|
690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508
|
[Uimp] rated impulse withstand voltage
|
4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV communication circuit conforming to EN/IEC 60947-4-1
|
Short-circuit withstand
|
100 kA conforming to EN/IEC 60947-4-1
|
Associated fuse rating
|
4 A gG for output
0.5 A gG for control circuit
|
Protection type
|
Overload (long time)
Power factor variation
Phase unbalance
Reverse polarity protection
Locked rotor
Thermal overload protection
Earth-leakage protection
Thermal protection
Phase failure
Overload
Load fluctuation
|
Network and machine diagnosis type
|
Trip history information
Starting current and time
Fault recording
Running hours counter/operating time
Motor control command recording
Phase fault and earth fault trip counters
Waiting time after overload tripping
Remaining operating time before overload tripping
Trip context information
Event recording
|
Logic input number
|
6
|
Input current
|
3.1 mA at 100 V
7.5 mA at 240 V
|
Current state 0 guaranteed
|
Logic input: 0...40 V and <= 15 mA for 25 ms
|
Current state 1 guaranteed
|
Logic input: 79...264 V and >= 2 mA for 25 ms
|
Maximum output switching frequency
|
2 Hz
|
Load current
|
5 A at 250 V AC for logic output
5 A at 30 V DC for logic output
|
Permissible power
|
480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
|
Maximum operating rate
|
1800 cyc/h
|
Contacts type and composition
|
1 NO + 1 NC fault signal
3 NO
|
Metering type
|
Temperature
Earth-fault current
Phase current I1, I2, I3 RMS
Imbalance current
Average current Iavg
|
Measurement accuracy
|
5...15 % earth fault current internal measurement
1 % voltage (100...830 V)
3 % power factor
5 % earth fault current external measurement
+/- 30 min/year internal clock
0,02 temperature
1 % current
5 % active and reactive power
|
Overvoltage category
|
III
|
Connection pitch
|
5.08 mm
|
Connections - terminals
|
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end
|
Tightening torque
|
Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm
|
Pollution degree
|
3
|
Electromagnetic compatibility
|
Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
|
Width
|
91 mm
|
Height
|
61 mm
|
Depth
|
122.5 mm
|
Net weight
|
0.53 kg
|
Web services
|
Web server
|
Compatibility code
|
LTMR
|
Environment
Standards
|
IACS E10
CSA C22.2 No 14
EN 60947-4-1
IEC 60947-4-1
UL 508
|
Product certifications
|
NOM
LROS (Lloyds register of shipping)
DNV
C-Tick
ABS
ATEX
CSA
EAC
BV
GL
CCC
RMRoS
UL
KERI
RINA
|
Protective treatment
|
12 x 24 hour cycles conforming to EN/IEC 60068-2-30
48 h conforming to EN/IEC 60070-2-11
TH conforming to EN/IEC 60068
|
Fire resistance
|
650 °C conforming to EN/IEC 60695-2-12
960 °C conforming to UL 94
|
Ambient air temperature for operation
|
-20…60 °C
|
Ambient air temperature for storage
|
-40…80 °C
|
Operating altitude
|
<= 2000 m without derating
|
Mechanical robustness
|
Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
|
IP degree of protection
|
IP20
|
Packing Units
Unit Type of Package 1
|
PCE
|
Number of Units in Package 1
|
1
|
Package 1 Height
|
10.000 cm
|
Package 1 Width
|
7.000 cm
|
Package 1 Length
|
13.500 cm
|
Package 1 Weight
|
531.000 g
|
Unit Type of Package 2
|
S02
|
Number of Units in Package 2
|
10
|
Package 2 Height
|
15.000 cm
|
Package 2 Width
|
30.000 cm
|
Package 2 Length
|
40.000 cm
|
Package 2 Weight
|
5.614 kg
|
Offer Sustainability
Contractual warranty
|
|