Power quality analysis
|
Up to the 63rd harmonic
|
Metering type
|
Measured neutral current
Calculated ground current
|
Device application
|
Gateway
WAGES metering
Power monitoring
Multi-tariff
|
Type of measurement
|
Current
Voltage
Frequency
Power factor
Energy
Active and reactive power
|
Supply voltage
|
100...300 V DC
90...528 V AC 45...65 Hz
|
Network frequency
|
60 Hz
50 Hz
|
[In] rated current
|
1 A
5 A
|
Type of network
|
3P + N
3P
1P + N
|
Maximum power consumption in VA
|
16 VA at 480 V
|
Ride-through time
|
35 ms 120 V AC typical
129 ms 230 V AC typical
50 ms 125 V DC typical
|
Display type
|
Backlit LCD
|
Display resolution
|
128 x 128 pixels
|
Sampling rate
|
128 samples/cycle
|
Measurement current
|
50…10000 mA
|
Analogue input type
|
Voltage (impedance 5 MOhm)
Current (impedance <= 0.3 mOhm)
|
Measurement voltage
|
20…400 V AC 45...65 Hz between phase and neutral
20…828 V AC 45...65 Hz between phases
|
Frequency measurement range
|
45…65 Hz
|
Number of inputs
|
4 digital
|
Measurement accuracy
|
Apparent power +/- 0.5 %
Frequency +/- 0.05 %
Active energy +/- 0.2 %
Reactive energy +/- 1 %
Active power +/- 0.2 %
Voltage +/- 0.1 %
Power factor +/- 0.005
Current +/- 0.15 %
Reactive power +/- 1 %
|
Accuracy class
|
Class 0.2S active energy conforming to IEC 62053-22
|
Number of outputs
|
2 digital
|
Information displayed
|
Tariff (8)
|
Communication port protocol
|
Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V
JBUS
Modbus TCP/IP at 10/100 Mbit/s, insulation 2500 V
Ethernet Modbus TCP/IP daisy chain
BACnet IP
DNP3 over ethernet
|
Communication port support
|
RS485
ETHERNET
|
Communication gateway
|
Ethernet/serial
|
Data recording
|
Event logs
Maintenance logs
Min/max of instantaneous values
Data logs
Alarm logs
Time stamping
|
Memory capacity
|
1.1 MB
|
Web services
|
Alarm notification by e-mail
Diagnostic via predefined web pages
Web server
Real time viewing of data
|
Ethernet service
|
SNTP client
SNMP-Traps
|
Connections - terminals
|
Voltage circuit: screw terminal block4
Control circuit: screw terminal block2
Current transformer: screw terminal block6
RS485 link: screw terminal block4
Digital input: screw terminal block8
Digital output: screw terminal block4
Ethernet network: RJ45 connector2
|
Mounting mode
|
Flush-mounted
|
Mounting support
|
Framework
|
Standards
|
EN 50470-3
IEC 61557-12:2015
IEC 62053-22:2020
IEC 62053-24
IEC 60529
EN 50470-1
UL 61010-1
ANSI C12.20
IEC 62053-23:2020
IEC 62052-11:2020
IEC 62052-31:2015
|
Product certifications
|
CE conforming to IEC 61010-1
CULus conforming to UL 61010-1
BTL
|
Width
|
96 mm
|
Depth
|
72 mm
|
Height
|
96 mm
|
Net weight
|
450 g
|