Discrete output type
|
Relay
|
Nominal output current
|
8 A
|
Contacts type and composition
|
2 C/O timed contact, cadmium free
1 C/O timed and instantaneous contact, cadmium free
|
Time delay type
|
Power on-delay
On-delay and off-delay
Pulse delay
Asymmetrical on-delay and off-delay
Interval
Off-delay
Symmetrical flashing
Safe-guard
Star-delta
Asymmetrical flashing
Bistable
|
Time delay range
|
0.05 s...999 h
|
Product compatibility
|
NFC enabled mobile device
|
Control type
|
Without test button
|
[Us] rated supply voltage
|
24...240 V AC/DC
|
Release input voltage
|
<= 2.4 V
|
Voltage range
|
0.85...1.1 Un
|
Maximum RF power transmitted
|
0.0002 mW
|
NFC operating frequency
|
13.56 MHz
|
Supply frequency
|
50...60 Hz +/- 5 %
|
Connections - terminals
|
Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
|
Tightening torque
|
0.6…1 N.m conforming to IEC 60947-1
0.6…1.0 N.m conforming to IEC 60947-1
|
Housing material
|
Self-extinguishing
|
Repeat accuracy
|
+/- 0.2 % for 10 s...999 h time delay range
+/- 0.5 % for 100 ms...10 s time delay range
+/- 0.7 % for 50...100 ms time delay range
|
Temperature drift
|
+/- 0.05 %/°C
|
Voltage drift
|
+/- 0.2 %/V
|
Setting accuracy of time delay
|
+/- 1 % for 1...999 h time delay range at 25 °C
+/- 2 % for 1...3600 s time delay range at 25 °C
+/- 20 ms for 100 ms...10 s time delay range at 25 °C
+/- 30 ms for 50...100 ms time delay range at 25 °C
|
Time delay type
|
Power on-delay - A- Power on-delay relay
On-delay and off-delay - Ac- On-delay and off-delay relay w/ control signal
Pulse delay - Ad- Pulse delayed relay w/ control signal
Pulse delay - Ah- Pulse delayed relay (single cycle) w/ control signal
On-delay and off-delay - Ak- Asymmetrical on-delay and off -delay relay w/ control signal
Power on-delay - At- Power on-delay relay w/ pause/summation (Y1)
Interval - B- Single interval relay w/ control signal
Interval - Bw- Double interval relay w/ control signal
Off-delay - C- Off-delay relay w/ control signal
Symmetrical flashing - D- Symmetrical flashing relay (starting pulse-off)
Symmetrical flashing - Di- Symmetrical flashing relay (starting pulse-on)
Symmetrical flashing - Dt- Symmetrical flashing relay (starting pulse-off) w/ pause/summation (Y1)
Symmetrical flashing - Dit- Symmetrical flashing relay (starting pulse-on) w/ pause/summation (Y1)
Interval - H- Interval relay
Interval - Ht- Interval relay w/ pause/summation (Y1)
Asymmetrical flashing - Li- Asymmetrical flashing relay (starting pulse-on)
Asymmetrical flashing - Lt- Asymmetrical fl ashing relay (starting pulse-off) w/ pause/summation (Y1)
Asymmetrical flashing - Lit- Asymmetrical flashing relay (starting pulse-on) w/ pause/summation (Y1)
Safe-guard - N- Safe-guard relay
Safe-guard - O- Delayed Safe-guard relay
Pulse delay - P- Pulse delayed relay w/ fixed pulse length
Pulse delay - Pt- Pulse delayed relay w/ fixed pulse length and pause/summation
Star-delta - Qt- Star-delta relay (2 CO outputs w/ split common)
Star-delta - Qtt- Star-delta relay (2 CO outputs w/ split common) w/ pause/summation (Y1)
Bistable - TI- Bistable relay w/ control signal on
Bistable - Tt- Retriggerable bistable relay w/ control signal on
Interval - W- Interval relay w/ control signal off
Asymmetrical flashing - L- Asymmetrical flashing relay (starting pulse-off)
|
Control signal pulse width
|
100 ms with load in parallel
60 ms no-load
|
Insulation resistance
|
100 MOhm at 500 V DC conforming to IEC 60664-1
|
Recovery time
|
120 ms on de-energisation
|
Power consumption in VA
|
3 VA at 240 V AC
|
Power consumption in W
|
1.5 W at 240 V DC
0.6 W at 24 V DC
|
Switching capacity in VA
|
2000 VA
|
Minimum switching current
|
10 mA at 5 V
|
Maximum switching current
|
8 A
|
Maximum switching voltage
|
250 V
|
Electrical durability
|
100000 cycles for resistive load, 8 A at 250 V, AC
|
Mechanical durability
|
10000000 cycles
|
Rated impulse withstand voltage
|
5 kV 1.2/50 µs conforming to IEC 60664-1
|
Power on delay
|
100 ms
|
Creepage distance
|
4 kV/3 conforming to IEC 60664-1
|
Overvoltage category
|
III conforming to IEC 60664-1
|
Safety reliability data
|
MTTFd = 227.5 years 100 % duty cycle continuous operating condition at 30 °C
|
Mounting position
|
Any position
|
Mounting support
|
35 mm DIN rail conforming to IEC 60715
|
Status LED
|
LED Un: (steady), green for power ON
LED R1: (steady), amber for relay energised
LED R2: (steady), amber for relay energised
LED pairing: (steady), green for communication status
LED Un: (fast blinking), green for diagnosis mode
LED R1: (blinking), amber for timing in progress
LED R2: (blinking), amber for timing in progress
|
Maximum communication distance
|
10 mm
|
Function available
|
A- Power on-delay relay-2 C/O
Ac- On-delay and off-delay relay w/ control signal-2 C/O
Ad- Pulse delayed relay w/ control signal-2 C/O
Ah- Pulse delayed relay (single cycle) w/ control signal-2 C/O
Ak- Asymmetrical on-delay and off -delay relay w/ control signal-2 C/O
At- Power on-delay relay w/ pause/summation (Y1)-2 C/O
B- Single interval relay w/ control signal-2 C/O
Bw- Double interval relay w/ control signal-2 C/O
C- Off-delay relay w/ control signal-2 C/O
D- Symmetrical flashing relay (starting pulse-off)-2 C/O
Di- Symmetrical flashing relay (starting pulse-on)-2 C/O
Dt- Symmetrical flashing relay (starting pulse-off) w/ pause/summation (Y1)-2 C/O
Dit- Symmetrical flashing relay (starting pulse-on) w/ pause/summation (Y1)-2 C/O
H- Interval relay-2 C/O
Ht- Interval relay w/ pause/summation (Y1)-2 C/O
Li- Asymmetrical flashing relay (starting pulse-on)-2 C/O
Lt- Asymmetrical fl ashing relay (starting pulse-off) w/ pause/summation (Y1)-2 C/O
Lit- Asymmetrical flashing relay (starting pulse-on) w/ pause/summation (Y1)-2 C/O
N- Safe-guard relay-2 C/O
O- Delayed Safe-guard relay-2 C/O
P- Pulse delayed relay w/ fixed pulse length-2 C/O
Pt- Pulse delayed relay w/ fixed pulse length and pause/summation-2 C/O
Qt- Star-delta relay (2 CO outputs w/ split common)-2 C/O
Qtt- Star-delta relay (2 CO outputs w/ split common) w/ pause/summation (Y1)-2 C/O
TI- Bistable relay w/ control signal on-2 C/O
Tt- Retriggerable bistable relay w/ control signal on-2 C/O
W- Interval relay w/ control signal off-2 C/O
L- Asymmetrical flashing relay (starting pulse-off)-2 C/O
|
Operating system
|
Androidversion >= V7.0
IOSversion >= V14.5
|
Width
|
22.5 mm
|
Product weight
|
0.0904 kg
|
Number of functions
|
28
|
Immunity to microbreaks
|
10 ms
|
Dielectric strength
|
2.5 kV for 1 mA/1 minute at 50 Hz with between relay output and power supply with basic insulation
With basic insulation
|
Standards
|
IEC 61000-6-1
IEC 61000-6-2
IEC 61000-6-4
EN 61812-1
IEC 61000-6-3
|
Directives
|
2014/35/EU - low voltage directive
2014/53/EU - radio equipment directive
2014/30/EU - electromagnetic compatibility
|
Product certifications
|
CE
CSA
KC
UL
CCC
EAC
DNV-GL
|
Ambient air temperature for operation
|
-20…60 °C
|
Ambient air temperature for storage
|
-40…70 °C
|
IP degree of protection
|
IP40 housing: conforming to IEC 60529
IP40 front face: conforming to IEC 60529
IP20 terminals: conforming to IEC 60529
|
Pollution degree
|
3 conforming to IEC 60664-1
|
Vibration resistance
|
20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
|
Shock resistance
|
15 gn not operating for 11 ms conforming to IEC 60068-2-27
5 gn in operation for 11 ms conforming to IEC 60068-2-27
|
Relative humidity
|
95 % at 25…55 °C
|
Electromagnetic compatibility
|
Electrostatic discharge immunity test - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge immunity test - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4
Fast transients immunity test - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4
Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5
Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6
Electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3
Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11
Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11
Radiated emission class B conforming to EN 55022
Conducted emission class A conforming to EN 55022
Electromagnetic field immunity test - test level: 3 V/m level 2 (1.4 GHz...2 GHz) conforming to IEC 61000-4-3
Electromagnetic field immunity test - test level: 1 V/m level 1 (2...2.7 GHz) conforming to IEC 61000-4-3
|
Packaging without single use plastic
|
Yes
|
Packaging made with recycled cardboard
|
Yes
|
SCIP Number
|
7bdc2711-0ad2-427c-8ece-532c5e9f09d7
|
REACh Regulation
|
REACh Declaration
|
EU RoHS Directive
|
Pro-active compliance (Product out of EU RoHS legal scope)
|
Mercury free
|
Yes
|
RoHS exemption information
|
Yes
|
China RoHS Regulation
|
China RoHS declaration
|
Environmental Disclosure
|
Product Environmental Profile
|
Circularity Profile
|
End of Life Information
|
California proposition 65
|
WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
Take-back
|
No
|
Carbon footprint (kg CO2 eq, Total Life cycle)
|
64
|