This Application will be decommissioned as of January 7th 2025

RENF22R2MMW |
Schneider-Electric
 
RENF22R2MMW picture- web-product-data-sheet
RENF22R2MMW
multifunction relay, Harmony Timer Relays, 8A, 2CO, 0.05s to 999h asymmetrical on delay and off delay 24 to 240V AC DC
Schneider Electric
Characteristics
Main
Range of product Harmony Timer Relays
Product or component type NFC timer relay
Device short name RENF22
App for product Ecostruxure Industrial Device (downloadable from Google Play store or Apple Store)
Complementary
Discrete output type Relay
Nominal output current 8 A
Contacts type and composition 2 C/O timed contact, cadmium free
1 C/O timed and instantaneous contact, cadmium free
Time delay type Power on-delay
On-delay and off-delay
Pulse delay
Asymmetrical on-delay and off-delay
Interval
Off-delay
Symmetrical flashing
Safe-guard
Star-delta
Asymmetrical flashing
Bistable
Time delay range 0.05 s...999 h
Product compatibility NFC enabled mobile device
Control type Without test button
[Us] rated supply voltage 24...240 V AC/DC
Release input voltage <= 2.4 V
Voltage range 0.85...1.1 Un
Maximum RF power transmitted 0.0002 mW
NFC operating frequency 13.56 MHz
Supply frequency 50...60 Hz +/- 5 %
Connections - terminals Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Tightening torque 0.6…1 N.m conforming to IEC 60947-1
0.6…1.0 N.m conforming to IEC 60947-1
Housing material Self-extinguishing
Repeat accuracy +/- 0.2 % for 10 s...999 h time delay range
+/- 0.5 % for 100 ms...10 s time delay range
+/- 0.7 % for 50...100 ms time delay range
Temperature drift +/- 0.05 %/°C
Voltage drift +/- 0.2 %/V
Setting accuracy of time delay +/- 1 % for 1...999 h time delay range at 25 °C
+/- 2 % for 1...3600 s time delay range at 25 °C
+/- 20 ms for 100 ms...10 s time delay range at 25 °C
+/- 30 ms for 50...100 ms time delay range at 25 °C
Time delay type Power on-delay - A- Power on-delay relay
On-delay and off-delay - Ac- On-delay and off-delay relay w/ control signal
Pulse delay - Ad- Pulse delayed relay w/ control signal
Pulse delay - Ah- Pulse delayed relay (single cycle) w/ control signal
On-delay and off-delay - Ak- Asymmetrical on-delay and off -delay relay w/ control signal
Power on-delay - At- Power on-delay relay w/ pause/summation (Y1)
Interval - B- Single interval relay w/ control signal
Interval - Bw- Double interval relay w/ control signal
Off-delay - C- Off-delay relay w/ control signal
Symmetrical flashing - D- Symmetrical flashing relay (starting pulse-off)
Symmetrical flashing - Di- Symmetrical flashing relay (starting pulse-on)
Symmetrical flashing - Dt- Symmetrical flashing relay (starting pulse-off) w/ pause/summation (Y1)
Symmetrical flashing - Dit- Symmetrical flashing relay (starting pulse-on) w/ pause/summation (Y1)
Interval - H- Interval relay
Interval - Ht- Interval relay w/ pause/summation (Y1)
Asymmetrical flashing - Li- Asymmetrical flashing relay (starting pulse-on)
Asymmetrical flashing - Lt- Asymmetrical fl ashing relay (starting pulse-off) w/ pause/summation (Y1)
Asymmetrical flashing - Lit- Asymmetrical flashing relay (starting pulse-on) w/ pause/summation (Y1)
Safe-guard - N- Safe-guard relay
Safe-guard - O- Delayed Safe-guard relay
Pulse delay - P- Pulse delayed relay w/ fixed pulse length
Pulse delay - Pt- Pulse delayed relay w/ fixed pulse length and pause/summation
Star-delta - Qt- Star-delta relay (2 CO outputs w/ split common)
Star-delta - Qtt- Star-delta relay (2 CO outputs w/ split common) w/ pause/summation (Y1)
Bistable - TI- Bistable relay w/ control signal on
Bistable - Tt- Retriggerable bistable relay w/ control signal on
Interval - W- Interval relay w/ control signal off
Asymmetrical flashing - L- Asymmetrical flashing relay (starting pulse-off)
Control signal pulse width 100 ms with load in parallel
60 ms no-load
Insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1
Recovery time 120 ms on de-energisation
Power consumption in VA 3 VA at 240 V AC
Power consumption in W 1.5 W at 240 V DC
0.6 W at 24 V DC
Switching capacity in VA 2000 VA
Minimum switching current 10 mA at 5 V
Maximum switching current 8 A
Maximum switching voltage 250 V
Electrical durability 100000 cycles for resistive load, 8 A at 250 V, AC
Mechanical durability 10000000 cycles
Rated impulse withstand voltage 5 kV 1.2/50 µs conforming to IEC 60664-1
Power on delay 100 ms
Creepage distance 4 kV/3 conforming to IEC 60664-1
Overvoltage category III conforming to IEC 60664-1
Safety reliability data MTTFd = 227.5 years 100 % duty cycle continuous operating condition at 30 °C
Mounting position Any position
Mounting support 35 mm DIN rail conforming to IEC 60715
Status LED LED Un: (steady), green for power ON
LED R1: (steady), amber for relay energised
LED R2: (steady), amber for relay energised
LED pairing: (steady), green for communication status
LED Un: (fast blinking), green for diagnosis mode
LED R1: (blinking), amber for timing in progress
LED R2: (blinking), amber for timing in progress
Maximum communication distance 10 mm
Function available A- Power on-delay relay-2 C/O
Ac- On-delay and off-delay relay w/ control signal-2 C/O
Ad- Pulse delayed relay w/ control signal-2 C/O
Ah- Pulse delayed relay (single cycle) w/ control signal-2 C/O
Ak- Asymmetrical on-delay and off -delay relay w/ control signal-2 C/O
At- Power on-delay relay w/ pause/summation (Y1)-2 C/O
B- Single interval relay w/ control signal-2 C/O
Bw- Double interval relay w/ control signal-2 C/O
C- Off-delay relay w/ control signal-2 C/O
D- Symmetrical flashing relay (starting pulse-off)-2 C/O
Di- Symmetrical flashing relay (starting pulse-on)-2 C/O
Dt- Symmetrical flashing relay (starting pulse-off) w/ pause/summation (Y1)-2 C/O
Dit- Symmetrical flashing relay (starting pulse-on) w/ pause/summation (Y1)-2 C/O
H- Interval relay-2 C/O
Ht- Interval relay w/ pause/summation (Y1)-2 C/O
Li- Asymmetrical flashing relay (starting pulse-on)-2 C/O
Lt- Asymmetrical fl ashing relay (starting pulse-off) w/ pause/summation (Y1)-2 C/O
Lit- Asymmetrical flashing relay (starting pulse-on) w/ pause/summation (Y1)-2 C/O
N- Safe-guard relay-2 C/O
O- Delayed Safe-guard relay-2 C/O
P- Pulse delayed relay w/ fixed pulse length-2 C/O
Pt- Pulse delayed relay w/ fixed pulse length and pause/summation-2 C/O
Qt- Star-delta relay (2 CO outputs w/ split common)-2 C/O
Qtt- Star-delta relay (2 CO outputs w/ split common) w/ pause/summation (Y1)-2 C/O
TI- Bistable relay w/ control signal on-2 C/O
Tt- Retriggerable bistable relay w/ control signal on-2 C/O
W- Interval relay w/ control signal off-2 C/O
L- Asymmetrical flashing relay (starting pulse-off)-2 C/O
Operating system Androidversion >= V7.0
IOSversion >= V14.5
Width 22.5 mm
Net weight 0.0904 kg
Number of functions 28
Environment
Immunity to microbreaks 10 ms
Dielectric strength 2.5 kV for 1 mA/1 minute at 50 Hz with between relay output and power supply with basic insulation
With basic insulation
Standards IEC 61000-6-1
IEC 61000-6-2
IEC 61000-6-4
EN 61812-1
IEC 61000-6-3
Directives 2014/35/EU - low voltage directive
2014/53/EU - radio equipment directive
2014/30/EU - electromagnetic compatibility
Product certifications CE
CSA
KC
UL
CCC
EAC
DNV-GL
Ambient air temperature for operation -20…60 °C
Ambient air temperature for storage -40…70 °C
IP degree of protection IP40 housing: conforming to IEC 60529
IP40 front face: conforming to IEC 60529
IP20 terminals: conforming to IEC 60529
Pollution degree 3 conforming to IEC 60664-1
Vibration resistance 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
Shock resistance 15 gn not operating for 11 ms conforming to IEC 60068-2-27
5 gn in operation for 11 ms conforming to IEC 60068-2-27
Relative humidity 95 % at 25…55 °C
Electromagnetic compatibility Electrostatic discharge immunity test - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge immunity test - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4
Fast transients immunity test - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4
Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5
Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6
Electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3
Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11
Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11
Radiated emission class B conforming to EN 55022
Conducted emission class A conforming to EN 55022
Electromagnetic field immunity test - test level: 3 V/m level 2 (1.4 GHz...2 GHz) conforming to IEC 61000-4-3
Electromagnetic field immunity test - test level: 1 V/m level 1 (2...2.7 GHz) conforming to IEC 61000-4-3
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 2.4 cm
Package 1 Width 8.05 cm
Package 1 Length 9.45 cm
Package 1 Weight 103.635 g
Unit Type of Package 2 S02
Number of Units in Package 2 40
Package 2 Height 15.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 4.616 kg
Unit Type of Package 3 P06
Number of Units in Package 3 640
Package 3 Height 70.0 cm
Package 3 Width 60.0 cm
Package 3 Length 80.0 cm
Package 3 Weight 84.13 kg
Offer Sustainability
Packaging without single use plastic Yes
Packaging made with recycled cardboard Yes
SCIP Number 7bdc2711-0ad2-427c-8ece-532c5e9f09d7
REACh Regulation
print REACh Declaration
EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free Yes
Sustainable packaging Yes
RoHS exemption information
print Yes
China RoHS Regulation
print China RoHS declaration
Environmental Disclosure
print Product Environmental Profile
Circularity Profile
print End of Life Information
California proposition 65 WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Take-back No
Carbon footprint (kg.eq.CO2 per CR, Total Life cycle) 64