Maximum switching voltage
|
250 V AC
|
[Un] rated nominal voltage
|
380...415 V AC/DC 50/60 Hz, non self-powered
|
Supply voltage limits
|
323…456.5 V AC
|
Output contacts
|
2 C/O
|
Nominal output current
|
8 A
|
Delay at power up
|
0.6 s
|
Maximum electrode voltage
|
12 V AC
|
Maximum electrode current
|
1 mA
|
Repeat accuracy
|
+/- 2 % for time delay
|
Measurement error
|
< 1 % over the whole range with voltage variation
0.05 %/°C with temperature variation
|
Maximum cable distance between devices
|
1000 m between probe and delay
|
Sensitivity scale
|
5...100 kOhm St (Standard Sensitivity)
|
Sensitivity adjustment
|
5…100 %
|
Maximum supply current for sensors
|
1 mA
|
Cable capacitance
|
1 nF at HS (High Sensitivity) for probe cable
2.2 nF at St (Standard Sensitivity) for probe cable
4.7 nF at LS (Low Sensitivity) for probe cable
|
Overvoltage category
|
III conforming to IEC 60664-1
|
Insulation
|
Between supply and measurement
|
Connections - terminals
|
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
|
Tightening torque
|
0.6…1 N.m conforming to IEC 60947-1
|
Housing material
|
Self-extinguishing plastic
|
Mounting support
|
35 mm DIN rail conforming to IEC 60715
|
Mounting position
|
Any position
|
Electrical durability
|
100000 cycles
|
Mechanical durability
|
10000000 cycles
|
Contacts material
|
Cadmium free
|
Measurement range
|
5...100 kOhm
|
Safety reliability data
|
MTTFd = 125.5 years
B10d = 120000
|
Width
|
22.5 mm
|
Control type
|
With test button
|
Net weight
|
0.1 kg
|
Immunity to microbreaks
|
100 ms DC
90 ms AC
|
Electromagnetic compatibility
|
Immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1
Immunity for industrial environments conforming to IEC 61000-6-2
Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3
Emission standard for industrial environments conforming to IEC 61000-6-4
Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4
Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5
Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5
Conducted and radiated emissions class B group 1 conforming to CISPR 11
Conducted and radiated emissions class B conforming to CISPR 22
|
Standards
|
IEC 60255-1
|
Product certifications
|
CSA
GL
RCM
UL
EAC
CE
CCC
|
Ambient air temperature for storage
|
-40…70 °C
|
Relative humidity
|
93…97 % at 25…55 °C conforming to IEC 60068-2-30
|
Vibration resistance
|
0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
|
Shock resistance
|
15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27
5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
|
IP degree of protection
|
IP20 (terminals) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
|
Pollution degree
|
3 conforming to IEC 60664-1
|
Dielectric test voltage
|
2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27
|
Packaging without single use plastic
|
Yes
|
Packaging made with recycled cardboard
|
Yes
|
SCIP Number
|
5e3fdf99-611b-4d07-ad17-6eba84ab488b
|
REACh Regulation
|
REACh Declaration
|
EU RoHS Directive
|
Pro-active compliance (Product out of EU RoHS legal scope)
|
Mercury free
|
Yes
|
Sustainable packaging
|
Yes
|
RoHS exemption information
|
Yes
|
China RoHS Regulation
|
China RoHS declaration
|
Environmental Disclosure
|
Product Environmental Profile
|
Circularity Profile
|
End of Life Information
|
WEEE
|
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
|
California proposition 65
|
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
Take-back
|
No
|
Carbon footprint (kg.eq.CO2 per CR, Total Life cycle)
|
43
|