3-phase control relay, Harmony Control Relays, 8A, 2CO, overfrequency and underfrequency, 208…480V AC
Schneider Electric
Characteristics
Main
Range of product Harmony Control Relays
Relay type Control relay
Product or component type NFC control relay
Network number of phases 3 phases
Relay name RMNF22
Relay monitored parameters Phase sequence
Phase failure detection
Overvoltage detection
Undervoltage detection
Overfrequency and underfrequency
Asymmetry
App for product Ecostruxure Industrial Device (downloadable from Google Play store or Apple Store)
Product compatibility NFC enabled mobile device
Time delay type Adjustable 0.1 s...1 min Tt- time delay upon fault
Switching capacity in VA 2000 VA
Complementary
NFC operating frequency 13.56 MHz
Maximum RF power transmitted 0.0002 mW
Reset time 1500 ms at maximum voltage
Maximum switching voltage 250 V AC
Minimum switching current 100 mA at 6 V
Maximum switching current 8 A AC
Supply voltage limits 166.4…576 V AC line to line
96…332.4 V AC line to neutral
Power consumption in VA 4 VA at 480 V AC 60 Hz
On-load factor 100 %
Supply voltage frequency 50...60 Hz +/- 10 %
Output contacts 2 C/O
Measurement range 208...480 V AC
Setting accuracy of the switching threshold +/- (1.5 % + 1 V)
Setting accuracy of time delay +/- 3 % for 10 s...60 min time delay range
+/- 300 ms for 0...10 s time delay range
Hysteresis 3 % of fixed for phase failure detection
Alarm threshold 166...576 V adjustable overvoltage and undervoltage detection (line to line)
96...332 V adjustable overvoltage and undervoltage detection (line to neutral)
5...150 V adjustable asymmetry
45...66 Hz adjustable overfrequency or underfrequency
Run-up delay at power-up max 650 ms
Maximum measuring cycle 150 ms measurement cycle as true rms value
Threshold adjustment voltage 2...20 % of Un selected
Adjustment of asymmetry threshold 2...20 % of Un selected
Repeat accuracy +/- 0.5 % for input circuit
+/- 3 % for time delay
Setting accuracy of the switching threshold +/- (1.5 % + 1 V)
Measurement error < 0.05 %/Hz with frequency variation
< 0.05 %/°C with temperature variation
Response time <= 300 ms
Insulation resistance > 100 MOhm at 500 V DC conforming to IEC 60255-27
[Ui] rated insulation voltage 400 V
[Uimp] rated impulse withstand voltage 4 kV during 1.2/50 µs
Dielectric test voltage 2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27
Mounting position Any position
Connections - terminals Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 2 x 0.5...2 x 1.5 mm² (AWG 20...AWG 16) flexible with cable end
Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 1 x 0.5...1 x 2.5 mm² (AWG 20...AWG 14) flexible with cable end
Tightening torque 0.6…1 N.m conforming to IEC 60947-1
0.60…0.99 N.m conforming to IEC 60947-1
Housing material Self-extinguishing plastic
Local signalling LED Un: (steady), green for power ON
LED R1: (steady), amber for relay energised
LED R1: (blinking), amber for timing in progress
LED R2: (steady), amber for relay energised
LED R2: (blinking), amber for timing in progress
LED PL: (steady), red for alarm phase failure triggered
LED PS: (blinking), red for alarm phase sequence failure triggered
LED UV: (steady), red for alarm undervoltage failure triggered
LED OV: (blinking), red for alarm overvoltage failure triggered
LED UF: (steady), red for alarm underfrequency failure triggered
LED OF: (blinking), red for alarm overfrequency failure triggered
LED ASYM: (steady), red for alarm asymmentry failure triggered
Mounting support 35 mm DIN rail conforming to IEC 60715
Electrical durability 100000 cycles
Mechanical durability 10000000 cycles
Utilisation category AC-15 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
AC-1 conforming to IEC 60947-4-1
DC-1 conforming to IEC 60947-4-1
[Ith] conventional free air thermal current 8 A
[Un] rated nominal voltage 208...480 V AC 50/60 Hz, non self-powered
120...277 V AC 50/60 Hz, non self-powered
Operating system Androidversion >= V7.0
IOSversion >= V14.5
Contacts material Cadmium free
Control type Without test button
Width 22.5 mm
Height 90 mm
Depth 99 mm
Contacts type and composition 2 C/O
Net weight 0.125 kg
Environment
Immunity to microbreaks 10 ms
Electromagnetic compatibility Voltage dips and interruptions immunity test - test level: 70 % (25/30 cycles) conforming to IEC 61000-4-11
Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3
Immunity for industrial environments conforming to IEC 61000-6-2
1 MHz damped oscillating wave - test level: 2.5 kV CM, 1 kV DM criteria B conforming to IEC 61000-4-18
Voltage dips and interruptions immunity test - test level: 0 % (0.5...25 cycles) conforming to IEC 61000-4-11
Magnetic field at power frequency - test level: 30 A/m (continuous)-300 A/m (1-3 s) level 4 conforming to IEC 61000-4-8
Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5
Immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1
Voltage dips and interruptions immunity test - test level: 40 % (10/12 cycles) conforming to IEC 61000-4-11
Voltage interruptions - test level: 0 % criteria C (250/300 cycles) conforming to IEC 61000-4-29
Electrical fast transient/burst immunity test - test level: 4 kV criteria B (direct) conforming to IEC 61000-4-4
Emission standard for industrial environments conforming to IEC 61000-6-4
Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5
Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Conducted RF disturbances level 3 conforming to IEC 61000-4-6
Standards IEC 60255-1
Product certifications CE
UL
CSA
CCC
EAC
RCM
Directives 2014/30/EU - electromagnetic compatibility
2014/35/EU - low voltage directive
2014/53/EU - radio equipment directive
Ambient air temperature for storage -40…70 °C
Ambient air temperature for operation -20…60 °C
Relative humidity 93…97 % at 25…55 °C conforming to IEC 60068-2-30
Vibration resistance 0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
1 gn (f= 58.1…150 Hz) not in operation conforming to IEC 60068-2-6
0.035 mm (f= 10…58.1 Hz) in operation conforming to IEC 60068-2-6
0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
Shock resistance 15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27
5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
IP degree of protection IP20 (terminals) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529
Pollution degree 3 conforming to IEC 60664-1
3 conforming to UL 508
Overvoltage category III conforming to IEC 60664-1
III conforming to UL 508
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 9.6 cm
Package 1 Width 2.5 cm
Package 1 Length 10.8 cm
Package 1 Weight 136.0 g
Unit Type of Package 2 S02
Number of Units in Package 2 36
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 5.578 kg
Unit Type of Package 3 P06
Number of Units in Package 3 576
Package 3 Height 75 cm
Package 3 Width 60 cm
Package 3 Length 80 cm
Package 3 Weight 98 kg
Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
print REACh Declaration
EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free Yes
China RoHS Regulation
print China RoHS declaration
RoHS exemption information
print Yes
Environmental Disclosure
print Product Environmental Profile
Circularity Profile
print End of Life Information
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
California proposition 65 WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov