Format of the drive
|
Block
|
Network number of phases
|
Single phase
|
[Us] rated supply voltage
|
100...120 V - 15...10 %
200...230 V - 15...10 %
|
Supply voltage type
|
AC/DC
|
Network frequency limits
|
50…60 Hz (- 15...10 %)
|
Communication interface
|
Profibus DP fieldbus, integrated
|
Maximum motor phase current
|
6.8 A
|
Current consumption
|
5 A 230 V main supply
7 A 115 V main supply
<= 0.2 mA 24 V control voltage
|
Nominal power
|
280 W at 115 V
420 W at 230 V
|
Short-circuit current
|
0.5 kA
|
Power losses
|
<= 65 W
|
Associated fuse rating
|
10 A at 115 V
6 A at 230 V
|
Overvoltage category
|
III
|
Inrush current
|
60 A
|
Maximum leakage current
|
30 mA <10 m IEC 60990-3
|
Voltage state 0 guaranteed
|
-3...5 V for 24 V input signals
|
Voltage state 1 guaranteed
|
15...30 V for 24 V input signals
|
Input current
|
10 mA for 24 V input signals
|
Maximum input frequency
|
200 kHz for signal input ENC_A, ENC_B, ENC_I - control type pulse/direction
400 kHz for signal input ENC_A, ENC_B, ENC_I - control type A/B
|
Maximum output frequency
|
400 kHz for pulse/direction interface A/B
200 kHz for pulse/direction interface pulse/direction
|
Maximum switching current
|
50 mA (24 V output signals)
|
Maximum voltage drop
|
<1 V 50 mA load for 24 V output signals
|
Physical interface
|
RS422 - pulse/direction interface
RS422 - signal input ENC_A, ENC_B, ENC_I
|
Output voltage
|
<= 30 V (24 V output signals)
4.75...5.25 V (ENC+5V_OUT signal output)
|
Input voltage
|
24 V -15 %/+20 % for 24 V control voltage
|
Residual ripple
|
< 5 % (24 V control voltage)
|
Resistance
|
5 kOhm (pulse/direction interface)
|
Safety function
|
Safe torque off safety function for machine conforming to IEC/EN 61800-5-2
Safe torque off safety function for machine conforming to ISO 13849-1 level d
Safe torque off safety function for system process conforming to EN/IEC 61508 level SIL2
Safe torque off safety function for system process conforming to IEC/EN 61800-5-2
|
Type of cooling
|
Fan
|
Maximum mechanical speed
|
3000 rpm
|
Height
|
145 mm
|
Width
|
72 mm
|
Depth
|
140 mm
|
Shock resistance
|
15 gn for 11 ms conforming to IEC 60068-2-27
|
Product weight
|
1.2 kg
|
Electromagnetic compatibility
|
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
|
Standards
|
EN/IEC 61800-3
EN/IEC 61800-5-1
|
Product certifications
|
UL
cUL
TÜV
|
Marking
|
CE
|
Ambient air temperature for operation
|
0…50 °C
|
Ambient air temperature for storage
|
-25…70 °C
|
Pollution degree
|
Level 2
|
Relative humidity
|
5…85 % without condensation
|
Operating altitude
|
<= 1000 m without derating
> 1000...< 2000 m without derating (maximum ambient temperature 40°C, no protective film, lateral distance of > 50mm)
|
Vibration resistance
|
1 gn (f= 13…150 Hz) conforming to IEC 60068-2-6
1.5 mm (f= 3…13 Hz) conforming to IEC 60068-2-6
|
IP degree of protection
|
IP20
On upper part: IP40 (without removal of protective film)
|
Packaging without single use plastic
|
No
|
Packaging made with recycled cardboard
|
Yes
|
SCIP Number
|
19ee4950-c76c-48d9-8353-203688a9f056
|
REACh Regulation
|
REACh Declaration
|
EU RoHS Directive
|
Pro-active compliance (Product out of EU RoHS legal scope)
|
Mercury free
|
Yes
|
RoHS exemption information
|
Yes
|
China RoHS Regulation
|
China RoHS declaration
|
Environmental Disclosure
|
Product Environmental Profile
|
Circularity Profile
|
End of Life Information
|
PVC free
|
Yes
|
California proposition 65
|
"WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov"
|
Take-back
|
No
|
Carbon footprint (kg CO2 eq, Total Life cycle)
|
586
|