Range compatibility
|
Modicon LMC058
Modicon M258
|
Product compatibility
|
Logic controller
Motion controller
|
Measurement resolution
|
0.1 °C
|
Colour
|
White
|
Input filtering
|
1...66.7 ms configurable by software
|
Measurement error
|
+/- 0.1 % of full scale - 210...1200 °C thermocouple J at 25 °C
+/- 0.11 % of full scale - 270...1300 °C thermocouple N at 25 °C
+/- 0.11 % of full scale - 270...1372 °C thermocouple K at 25 °C
+/- 0.17 % of full scale - 50...1768 °C thermocouple S at 25 °C
|
Temperature coefficient
|
0.01 %FS/°C, analogue input type: thermocouple
|
Non-linearity
|
+/- 0.001 %FS, analogue input type: thermocouple
|
Type of cable
|
Shielded cable
|
Isolation
|
No insulation between channels
500 Vrms AC insulation between channel and bus
|
Supply
|
Internal
|
[Us] rated supply voltage
|
24 V DC -15...20 %
|
Common mode rejection
|
> 70 dB
|
Local signalling
|
1 LED green for power supply
1 LED red for power supply
6 LEDs green for input status
|
Current consumption
|
2 mA at 5 V DC bus
38 mA at 24 V DC input/output
|
Maximum power dissipation in W
|
0.92 W
|
Marking
|
CE
|
Net weight
|
0.025 kg
|
Standards
|
IEC 61131-2
CSA C22.2 No 213
UL 508
CSA C22.2 No 142
|
Product certifications
|
CSA
GOST-R
cULus
C-Tick
|
Ambient air temperature for operation
|
0…55 °C without derating (horizontal installation)
0…60 °C with derating factor (horizontal installation)
0…50 °C (vertical installation)
|
Ambient air temperature for storage
|
-25…70 °C
|
Relative humidity
|
5…95 % without condensation
|
IP degree of protection
|
IP20 conforming to IEC 61131-2
|
Pollution degree
|
2 conforming to IEC 60664
|
Operating altitude
|
0...2000 m
|
Storage altitude
|
0…3000 m
|
Vibration resistance
|
1 gn at 8.4…150 Hz on DIN rail
3.5 mm at 5…8.4 Hz on DIN rail
|
Shock resistance
|
15 gn for 11 ms
|
Resistance to electrostatic discharge
|
4 kV on contact conforming to IEC 61000-4-2
8 kV in air conforming to IEC 61000-4-2
|
Resistance to electromagnetic fields
|
1 V/m 2...2.7 GHz conforming to IEC 61000-4-3
10 V/m 80...2000 MHz conforming to IEC 61000-4-3
|
Resistance to fast transients
|
1 kV (I/O) conforming to IEC 61000-4-4
1 kV (shielded cable) conforming to IEC 61000-4-4
2 kV (power lines) conforming to IEC 61000-4-4
|
Surge withstand
|
0.5 kV differential mode conforming to IEC 61000-4-5
1 kV common mode conforming to IEC 61000-4-5
|
Electromagnetic compatibility
|
EN/IEC 61000-4-6
|
Disturbance radiated/conducted
|
CISPR 11
|