VW3A4702
EMC radio interference input filter, for variable speed drive, 3 phase supply
|
|
|
Main
Range of product
|
Altivar
|
Product or component type
|
EMC input filter
|
Range compatibility
|
Altivar Process ATV600
Altivar Process ATV900
|
Product compatibility
|
Variable speed drive ATV630 wall mount, motor: 3 kW, 380...480 V
Variable speed drive ATV630 wall mount, motor: 4 kW, 380...480 V
Variable speed drive ATV630 wall mount, motor: 5.5 kW, 380...480 V
Variable speed drive ATV630 wall mount, motor: 2.2 kW, 200...240 V
Variable speed drive ATV630 wall mount, motor: 3 kW, 200...240 V
Variable speed drive ATV650 wall mount, motor: 3 kW, 380...480 V
Variable speed drive ATV650 wall mount, motor: 4 kW, 380...480 V
Variable speed drive ATV650 wall mount, motor: 5.5 kW, 380...480 V
Variable speed drive ATV930 wall mount, motor: 3 kW, 380...480 V
Variable speed drive ATV930 wall mount, motor: 4 kW, 380...480 V
Variable speed drive ATV930 wall mount, motor: 5.5 kW, 380...480 V
Variable speed drive ATV930 wall mount, motor: 2.2 kW, 200...240 V
Variable speed drive ATV930 wall mount, motor: 3 kW, 200...240 V
Variable speed drive ATV950 wall mount, motor: 3 kW, 380...480 V
Variable speed drive ATV950 wall mount, motor: 4 kW, 380...480 V
Variable speed drive ATV950 wall mount, motor: 5.5 kW, 380...480 V
|
Product specific application
|
Radio interference input filter
|
[In] rated current
|
15 A
|
Thermal losses
|
2.25 W
|
Network number of phases
|
Three phase
|
Complementary
Electrical connection
|
Terminal 4 mm² AWG 12
|
Maximum motor cable length
|
150 m shielded motor cable 4 kHz conforming to IEC 61800-3 category C2, 380...480 V
300 m shielded motor cable 4 kHz conforming to IEC 61800-3 category C3, 380...480 V
150 m shielded motor cable 4 kHz conforming to IEC 61800-3 category C2, 200...240 V
300 m shielded motor cable 4 kHz conforming to IEC 61800-3 category C3, 200...240 V
50 m shielded motor cable 4 kHz conforming to IEC 61800-3 category C1, 200...240 V
50 m shielded motor cable 4 kHz conforming to IEC 61800-3 category C1, 380...480 V
|
Maximum earth leakage current
|
7.6 mA at 400 V 50 Hz TN
7.6 mA at 400 V 50 Hz TT
|
Power supply voltage
|
200…240 V
380…480 V
|
Tolerance
|
10 %
|
Mechanical robustness
|
Shocks class 3M4 conforming to IEC 60721-3-3
Vibrations class 3M4 conforming to IEC 60721-3-3
|
Width
|
75 mm
|
Height
|
240 mm
|
Depth
|
140 mm
|
Net weight
|
2.4 kg
|
Environment
IP degree of protection
|
IP20mounting side by side
IP21with kit VW3A47902
|
Relative humidity
|
5…95 % without condensation conforming to IEC 61800-5-1
|
Ambient air temperature for operation
|
-10…50 °C (without current derating)
50…60 °C (with current derating 1.5 % per °C)
|
Ambient air temperature for storage
|
-40…70 °C
|
Operating altitude
|
0...1000 m without current derating
1000...4000 m with current derating 1 % per 100 m
|
Standards
|
IEC 61800-3
|
Packing Units
Unit Type of Package 1
|
PCE
|
Number of Units in Package 1
|
1
|
Package 1 Height
|
14.500 cm
|
Package 1 Width
|
20.000 cm
|
Package 1 Length
|
32.000 cm
|
Package 1 Weight
|
2.501 kg
|
Unit Type of Package 2
|
P06
|
Number of Units in Package 2
|
12
|
Package 2 Height
|
45.000 cm
|
Package 2 Width
|
80.000 cm
|
Package 2 Length
|
60.000 cm
|
Package 2 Weight
|
39.452 kg
|
Offer Sustainability
Packaging without single use plastic
|
No
|
Packaging made with recycled cardboard
|
No
|
REACh Regulation
|
REACh Declaration
|
REACh free of SVHC
|
Yes
|
EU RoHS Directive
|
Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration
|
Toxic heavy metal free
|
Yes
|
Mercury free
|
Yes
|
RoHS exemption information
|
Yes
|
China RoHS Regulation
|
China RoHS declaration
|
California proposition 65
|
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
Take-back
|
No
|
|
|