VW3A5216
Sinus filter - 28 A - for Altivar Process variable speed drives
|
|
|
Main
Product or component type
|
Sinus filter
|
Range compatibility
|
Altivar Process ATV900
Altivar Process ATV600
|
Product specific application
|
Output filter
|
[In] rated current
|
28 A
|
Thermal losses
|
280 W, 115 °C
|
Product compatibility
|
ATV630 variable speed drive wall mount - 11 kW, 500...690 V three phase
ATV630 variable speed drive wall mount - 15 kW, 500...690 V three phase
ATV630 variable speed drive wall mount - 18.5 kW, 500...690 V three phase
ATV630 variable speed drive wall mount - 22 kW, 500...690 V three phase
ATV930 variable speed drive wall mount - 11 kW, 500...690 V three phase
ATV930 variable speed drive wall mount - 15 kW, 500...690 V three phase
ATV930 variable speed drive wall mount - 18.5 kW, 500...690 V three phase
ATV930 variable speed drive wall mount - 22 kW, 500...690 V three phase
ATV630 variable speed drive wall mount, 15 hp, 600 V three phase
ATV630 variable speed drive wall mount, 20 hp, 600 V three phase
ATV630 variable speed drive wall mount, 25 hp, 600 V three phase
ATV630 variable speed drive wall mount, 30 hp, 600 V three phase
ATV930 variable speed drive wall mount, 15 hp, 600 V three phase
ATV930 variable speed drive wall mount, 20 hp, 600 V three phase
ATV930 variable speed drive wall mount, 25 hp, 600 V three phase
ATV930 variable speed drive wall mount, 30 hp, 600 V three phase
|
Switching frequency
|
2 kHz
|
Maximum output frequency
|
70 Hz
|
Maximum permissible voltage
|
690 V AC
|
Complementary
Electrical connection
|
Terminal
|
Max current
|
1.5 x nominal current (duration = 60 s)
|
Product weight
|
25.4 kg
|
Environment
IP degree of protection
|
IP00
|
Pollution degree
|
2 conforming to EN 50178
|
Vibration resistance
|
1 gn (f= 13…200 Hz) conforming to IEC 60068-2
1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2
|
Shock resistance
|
15 gn for 11 ms conforming to IEC 60068-2-27
|
Relative humidity
|
0…95 %
|
Ambient air temperature for operation
|
-10…45 °C
|
Ambient air temperature for storage
|
-40…65 °C
|
Operating altitude
|
<= 1000 m without current derating
1000...3000 m with current derating 1 % per 100 m
|
Standards
|
UL 508
|
Packing Units
Unit Type of Package 1
|
PCE
|
Number of Units in Package 1
|
1
|
Package 1 Height
|
32.0 cm
|
Package 1 Width
|
42.0 cm
|
Package 1 Length
|
55.0 cm
|
Package 1 Weight
|
34.0 kg
|
Offer Sustainability
Packaging without single use plastic
|
No
|
Packaging made with recycled cardboard
|
No
|
REACh Regulation
|
REACh Declaration
|
REACh free of SVHC
|
Yes
|
EU RoHS Directive
|
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
|
RoHS exemption information
|
Yes
|
China RoHS Regulation
|
China RoHS declaration
|
Take-back
|
No
|
|
|