XCSD3918P20
Safety limit switch, Telemecanique Safety switches XCS, metal, rotary lever, 2NC+1 NO, 1 entry tapped M20 x 1.5
|
|
|
Main
Range of product
|
Telemecanique Safety switches XCS
|
Product or component type
|
Safety limit switch
|
Component name
|
XCSD
|
Design
|
Compact
|
Material
|
Metal
|
Head type
|
Rotary head
|
Protection technology
|
Plastic protective cover, secured by 5-lobe socket head safety screw
|
Type of operator
|
Thermoplastic roller lever
|
Contacts type and composition
|
1 NC + 1 NC + 1 NO
|
Contact operation
|
Snap action
|
Cable entry
|
1 entry tapped for M20 x 1.5
|
Complementary
Electrical connection
|
Terminal
|
Clamping connection capacity
|
1 x 0.34...2 x 0.75 mm²
|
Switch actuation
|
By 30° cam
|
Number of poles
|
3
|
Positive opening
|
With NC contact
|
Mechanical durability
|
10000000 cycles
|
Minimum torque for tripping
|
0.1 N.m
|
Positive opening minimum torque
|
0.25 N.m
|
Maximum actuation speed
|
1.5 m/s
|
Contact code designation
|
B300, AC-15 (Ue = 240 V, Ie = 1.5 A) conforming to IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to IEC 60947-5-1 appendix A
|
[Ithe] conventional enclosed thermal current
|
6 A
|
[Ui] rated insulation voltage
|
300 V conforming to UL 508
400 V (pollution degree 3) conforming to IEC 60947-1
300 V conforming to CSA C22.2 No 14
|
[Uimp] rated impulse withstand voltage
|
4 kV conforming to IEC 60947-1
4 kV conforming to IEC 60664
|
Maximum resistance across terminals
|
25 MOhm conforming to IEC 60255-7 category 3
|
Short-circuit protection
|
6 A cartridge fuse type gG (gl)
|
Repeat accuracy
|
0.1 mm on tripping points, 1 million operating cycles for head with end plunger
|
Body material
|
Zamak
|
Head material
|
Zamak
|
Enclosure material
|
Plastic
|
Depth
|
35 mm
|
Height
|
122 mm
|
Width
|
34 mm
|
Net weight
|
0.255 kg
|
Environment
Standards
|
EN 1088/ISO 14119
UL 508
CSA C22.2 No 14
IEC 60204-1
IEC 60947-5-1
|
Product certifications
|
UL
CSA
|
Safety level
|
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
|
Safety reliability data
|
B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
|
Protective treatment
|
TC
|
Ambient air temperature for operation
|
-25…70 °C
|
Ambient air temperature for storage
|
-40…70 °C
|
Vibration resistance
|
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
|
Shock resistance
|
50 gn for 11 ms conforming to IEC 60068-2-27
|
Electrical shock protection class
|
Class I
|
IP degree of protection
|
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
|
IK degree of protection
|
IK06 conforming to IEC 62262
|
Packing Units
Unit Type of Package 1
|
PCE
|
Number of Units in Package 1
|
1
|
Package 1 Height
|
3.2 cm
|
Package 1 Width
|
5.4 cm
|
Package 1 Length
|
13.2 cm
|
Package 1 Weight
|
236.0 g
|
Unit Type of Package 2
|
S01
|
Number of Units in Package 2
|
15
|
Package 2 Height
|
15.0 cm
|
Package 2 Width
|
15.0 cm
|
Package 2 Length
|
40.0 cm
|
Package 2 Weight
|
3.74 kg
|
Offer Sustainability
EU RoHS Directive
|
Pro-active compliance (Product out of EU RoHS legal scope)
|
Mercury free
|
Yes
|
RoHS exemption information
|
Yes
|
Circularity Profile
|
No need of specific recycling operations
|
California proposition 65
|
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
Contractual warranty
|
|