Synchronisation time between inputs
|
< 0.5 ms
|
Power dissipation in W
|
3 W
|
Maximum number of I/O expansion module
|
14 with 128 discrete output(s) for input
14 with 16 discrete output(s) for output
|
Integrated connection type
|
Backplane expansion bus
USB 2.0 port
|
Data storage equipment
|
SD card (optional)
|
Inductive load
|
30 mH
|
Load capacitance
|
0.82 µF
|
Safety level
|
Can reach category 4 conforming to ISO 13849-1
Can reach PL = e conforming to ISO 13849-1
Type 4 conforming to IEC 61496-1
SILCL 3 conforming to IEC 62061
|
Quality labels
|
CE
|
Local signalling
|
1 LED green with PWR marking for power ON
1 LED green with RUN marking for RUN (status)
1 LED red with E IN marking for internal error
1 LED red with E EX marking for external error
1 LED orange with COM marking for communication
1 LED blue with EN marking for master enable
8 LEDs yellow with IN marking for input status
2 LEDs green/red with OUT marking for output status
2 LEDs yellow with RST marking for restart signal
2 LEDs yellow with STATUS marking for output channel
|
Connections - terminals
|
1 spring terminals, removable terminal block
2 spring terminals, removable terminal block
|
Cable cross section
|
0.2…2.5 mm² - AWG 24...AWG 14 flexible cablewithout cable end
0.25…2.5 mm² - AWG 23...AWG 14 flexible cablewith cable end, with bezel
0.2…2.5 mm² - AWG 24...AWG 14 solid cablewithout cable end
0.25…2.5 mm² - AWG 23...AWG 14 flexible cablewith cable end, without bezel
0.25…2.5 mm² - AWG 23...AWG 14 solid cablewithout cable end
0.5…1 mm² - AWG 20...AWG 18 flexible cablewith cable end, with double bezel
|
Mounting support
|
Omega 35 mm DIN rail conforming to EN 50022
|
Depth
|
114.5 mm
|
Height
|
99 mm
|
Width
|
22.5 mm
|
Product weight
|
0.25 kg
|
Standards
|
ISO 13849-1
IEC 62061
IEC 61800-5-1
IEC 61496-1
IEC 61508
|
Product certifications
|
RCM
TÜV
cULus
|
IP degree of protection
|
IP20
|
Ambient air temperature for operation
|
-10…55 °C
|
Ambient air temperature for storage
|
-20…85 °C
|
Relative humidity
|
10…95 %
|
Pollution degree
|
2
|
[Uimp] rated impulse withstand voltage
|
4 kV conforming to IEC 61800-5-1
|
Safety reliability data
|
PFHd = 6.06E-9 1/h
DC > 99 %
MTTFd < 100 years high
|
Insulation
|
250 V AC between power supply and housing conforming to IEC 61800-5-1
|
Overvoltage category
|
II
|
Electromagnetic compatibility
|
Electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to IEC 61000-4-2
Electrostatic discharge immunity test - test level: 20 kV (on air) conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3
|
Vibration resistance
|
+/-0.35 mm (f= 10…55 Hz) conforming to IEC 61496-1
|
Shock resistance
|
10 gn (duration = 16 ms) for 1000 shocks on each axis conforming to IEC 61496-1
|
Service life
|
20 year(s)
|