XPSMCMDI0800G
expansion module, Modicon MCM, 8 inputs, spring
|
|
|
Main
Range of product
|
Preventa Safety automation
|
Product or component type
|
Safe input expansion module
|
Device short name
|
XPSMCM
|
Electrical connection
|
Spring terminal
|
[Us] rated supply voltage
|
24 V - 20...20 % DC
|
Input type
|
8 digital
|
Output type
|
4 test for line control
|
Discrete input type
|
PNP
|
Discrete output type
|
PNP
|
Function of module
|
Monitoring safety detection for discrete input
Monitoring safety dialogue for discrete input
|
Complementary
Power consumption in W
|
3 W
|
Power dissipation in W
|
3 W
|
Integrated connection type
|
Backplane expansion bus
|
Number of terminal blocks
|
4
|
Connections - terminals
|
1 spring clamp terminals, removable terminal block
2 spring clamp terminals, removable terminal block
|
Safety level
|
Can reach category 4 conforming to ISO 13849-1
Can reach PL = e conforming to ISO 13849-1
Can reach SIL 3 conforming to IEC 61508
SILCL 3 conforming to IEC 62061
|
Quality labels
|
CE
|
Discrete input voltage
|
24 V DC
|
Local signalling
|
1 LED green with PWR marking for power ON
1 LED green with RUN marking for RUN (status)
1 LED red with E IN marking for internal error
1 LED red with E EX marking for external error
2 LEDs orange with ADDR marking for node address
8 LEDs yellow with IN marking for input status
|
Cable cross section
|
0.2…2.5 mm² - AWG 24...AWG 14 flexible cablewithout cable end
0.25…2.5 mm² - AWG 23...AWG 14 flexible cablewith cable end, with bezel
0.25…2.5 mm² - AWG 23...AWG 14 flexible cablewith cable end, without bezel
0.2…2.5 mm² - AWG 24...AWG 14 solid cablewithout cable end
0.5…1 mm² - AWG 20...AWG 18 flexible cablewith cable end, with double bezel
|
Mounting support
|
Omega 35 mm DIN rail conforming to EN 50022
|
Depth
|
22.5 mm
|
Height
|
99 mm
|
Width
|
114.5 mm
|
Net weight
|
0.23 kg
|
Environment
Standards
|
IEC 61508
ISO 13849-1
IEC 61800-5-1
IEC 62061
|
Product certifications
|
TÜV
RCM
cULus
|
IP degree of protection
|
IP20 (enclosure)
|
Ambient air temperature for operation
|
-10…55 °C
|
Ambient air temperature for storage
|
-20…85 °C
|
Relative humidity
|
10…95 %
|
Pollution degree
|
2
|
[Uimp] rated impulse withstand voltage
|
4 kV conforming to IEC 61800-5-1
|
Safety reliability data
|
PFHd = 5.75E-9 1/h
DC > 99 %
MTTFd < 100 years high
|
Insulation
|
250 V AC between power supply and housing conforming to IEC 61800-5-1
|
Overvoltage category
|
II
|
Electromagnetic compatibility
|
Electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to IEC 61000-4-2
Electrostatic discharge immunity test - test level: 20 kV (on air) conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3
|
Vibration resistance
|
+/-0.35 mm (f= 10…55 Hz) conforming to IEC 61496-1
|
Shock resistance
|
10 gn (duration = 16 ms) for 1000 shocks on each axis conforming to IEC 61496-1
|
Service life
|
20 year(s)
|
Packing Units
Unit Type of Package 1
|
PCE
|
Number of Units in Package 1
|
1
|
Package 1 Height
|
4.5 cm
|
Package 1 Width
|
12.8 cm
|
Package 1 Length
|
16.3 cm
|
Package 1 Weight
|
222.0 g
|
Unit Type of Package 2
|
S01
|
Number of Units in Package 2
|
6
|
Package 2 Height
|
15.0 cm
|
Package 2 Width
|
15.0 cm
|
Package 2 Length
|
40.0 cm
|
Package 2 Weight
|
1.579 kg
|
Offer Sustainability
REACh Regulation
|
REACh Declaration
|
REACh free of SVHC
|
Yes
|
EU RoHS Directive
|
Pro-active compliance (Product out of EU RoHS legal scope)
|
Mercury free
|
Yes
|
RoHS exemption information
|
Yes
|
China RoHS Regulation
|
China RoHS declaration
|
WEEE
|
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
|
California proposition 65
|
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
|
|