Schneider-Electric
 
XPSMP11123 picture- web-product-data-sheet
XPSMP11123
module XPS-MP - 2 independent functions - 24 V DC
Telemecanique
Characteristics
Main
Range of product Preventa Safety automation
Product or component type Safety controller with pre-defined function
Safety module name XPSMP
Safety module application 2 independent functions
Safety use category Category 4 maximum conforming to EN/IEC 60954-1
Type of start Automatic or unmonitored (configuration 1)
Automatic or unmonitored (configuration 10)
Automatic or unmonitored (configuration 11)
Automatic or unmonitored (configuration 14)
Automatic or unmonitored (configuration 3)
Automatic or unmonitored (configuration 5)
Automatic or unmonitored (configuration 7)
Monitored (configuration 12)
Monitored (configuration 13)
Monitored (configuration 15)
Monitored (configuration 2)
Monitored (configuration 4)
Monitored (configuration 6)
Monitored (configuration 8)
Monitored (configuration 9)
Checks Configuration (configuration 10)
Configuration (configuration 13)
Configuration (configuration 3)
Configuration (configuration 4)
Configuration (configuration 5)
Configuration (configuration 6)
Configuration (configuration 9)
Standards EN/IEC 60947-1 + A11
EN/IEC 60947-5-1
EN/IEC 60204-1
DIN V VDE 801 + A1
Product certifications UL
CSA
BIA
[Us] rated supply voltage 24 V DC - 20...20 %
Connections - terminals Captive screw clamp terminals flexible cable: 0.14...0.75 mm² without cable end, 2 wires
Captive screw clamp terminals solid cable: 0.14...0.75 mm² without cable end, 2 wires
Captive screw clamp terminals flexible cable: 0.14...2.5 mm² without cable end, 1 wire
Captive screw clamp terminals solid cable: 0.14...2.5 mm² without cable end, 1 wire
Captive screw clamp terminals flexible cable: 0.25...1 mm² with cable end, without bezel, 2 wires
Captive screw clamp terminals flexible cable: 0.25...1.5 mm² with cable end, with bezel, 1 wire
Captive screw clamp terminals flexible cable: 0.25...2.5 mm² with cable end, without bezel, 1 wire
Captive screw clamp terminals flexible cable: 0.5...1.5 mm² with cable end, with double bezel, 2 wires
Safety level Can reach PL e/category 4 conforming to EN/ISO 13849-1
Can reach SIL 3 conforming to EN/IEC 62061
Complementary
Function of module Configuration 0: functions disabled (factory setting)
Configuration 1: emergency stop monitoring 1-channel wiring, category 2
Configuration 10: enabling grip switch monitoring (3-position switch), category 4
Configuration 11: sensing mat and edges monitoring, category 3
Configuration 12: sensing mat and edges monitoring, category 3
Configuration 13: relay output safety light curtain monitoring, category 4
Configuration 14: coded magnetic switch monitoring, category 4
Configuration 15: coded magnetic switch monitoring, category 4
Configuration 2: emergency stop monitoring 1-channel wiring, category 2
Configuration 3: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
Configuration 4: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
Configuration 5: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
Configuration 6: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
Configuration 7: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
Configuration 8: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
Configuration 9: guard monitoring for injection presses and blowing machines, category 4
Synchronisation time between inputs 0.5 s (configuration 13)
1.5 s (configuration 14)
1.5 s (configuration 15)
1.5 s (configuration 5)
1.5 s (configuration 6)
1.5 s (configuration 9)
Unlimited (configuration 3)
Unlimited (configuration 4)
Unlimited (configuration 7)
Unlimited (configuration 8)
Power consumption in W 5 W
Input protection type Internal, electronic
[Uc] control circuit voltage 24 V
Maximum line resistance 100 Ohm <2000 m
Number of safety circuits 3 NO relays per function (6 NO total), volt-free
Number of additional circuits 3 solid state outputs
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 20 mA at 24 V for static output circuit
1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
Output thermal current 2 A for 1 output and 4 A for the other 2 outputs for relay
3.3 A for all 3 outputs relay simultaneously
6 A for 1 output and 2 A for the other 2 outputs for relay
[Ith] conventional free air thermal current 20 A
Associated fuse rating 4 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA for relay output
Minimum output voltage 17 V for relay output
Maximum response time on input open 30 ms
[Ui] rated insulation voltage 300 V (pollution degree 2) conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
[Uimp] rated impulse withstand voltage 4 kV overvoltage category III conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
Local signalling 12 LEDs
Mounting support 35 mm symmetrical DIN rail
Depth 114 mm
Height 99 mm
Width 45 mm
Net weight 0.32 kg
Environment
IP degree of protection IP20 (terminals)
IP40 (enclosure)
Ambient air temperature for operation -10…55 °C
Ambient air temperature for storage -25…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6.5 cm
Package 1 Width 12 cm
Package 1 Length 16 cm
Package 1 Weight 452 g
Unit Type of Package 2 S03
Number of Units in Package 2 20
Package 2 Height 30 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 9.762 kg
Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
print REACh Declaration
EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free Yes
RoHS exemption information
print Yes
China RoHS Regulation
print China RoHS declaration
Environmental Disclosure
print Product Environmental Profile
Circularity Profile
print End of Life Information
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
California proposition 65 "WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov"
Contractual warranty
Warranty 18 months