|
|
|
XPSUAT13A3AP
safety module, Harmony XPSU, Cat4, features XPSUAK with delayed outputs, 24V AC or DC, screw
|
|
|
Main
Range of product
|
Harmony Safety Automation
|
Product or component type
|
Safety module
|
Safety module name
|
XPSUAT
|
Safety module application
|
Monitoring antivalent contacts
For emergency stop, guard and light curtain monitoring
Monitoring of pressure-sensitive 4-wire protective devices
|
Function of module
|
Emergency stop button with 2 NC contacts
Guard monitoring with 1 or 2 limit switches
Monitoring 2 PNP sensors
Magnetic switch monitoring
Light curtain monitoring
RFID switch
Monitoring of electro-sensitive protection equipment (ESPE)
Sensing mat/edges
Proximity sensor monitoring
Monitoring 1 PNP + 1 NPN sensor
|
Safety level
|
Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1
Can reach SILCL 3 for normally open relay contact conforming to IEC 62061
Can reach SIL 3 for normally open relay contact conforming to IEC 61508
Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1
Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061
Can reach SIL 1 for normally closed relay contact conforming to IEC 61508
|
Safety reliability data
|
MTTFd > 30 years conforming to ISO 13849-1
Dcavg >= 99 % conforming to ISO 13849-1
PFHd = 0.94E-09 conforming to ISO 13849-1 for SS0
PFHd = 0.95E-09 conforming to ISO 13849-1 for SS1
HFT = 1 conforming to IEC 62061
PFHd = 0.94E-09 conforming to IEC 62061 for SS0
PFHd = 0.95E-09 conforming to IEC 62061 for SS1
SFF > 99% conforming to IEC 62061
HFT = 1 conforming to IEC 61508-1
PFHd = 0.94E-09 conforming to IEC 61508-1 for SS0
PFHd = 0.95E-09 conforming to IEC 61508-1 for SS1
SFF > 99% conforming to IEC 61508-1
Type = B conforming to IEC 61508-1
|
Electrical circuit type
|
NC pair
PNP pair
Antivalent pair
OSSD pair
|
Connections - terminals
|
Removable screw terminal block, 0.2...2.5 mm² solid or flexible
Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor
Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor
Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel
Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
|
[Us] rated supply voltage
|
24 V AC - 15...10 %
24 V DC - 20...20 %
|
Complementary
Synchronisation time between inputs
|
0.5 s
2 s
4 s
|
Type of start
|
Automatic/manual/monitored
|
Power consumption in W
|
3 W 24 V DC
|
Power consumption in VA
|
6.5 VA 24 V AC 50/60 Hz
|
Input protection type
|
Internal, electronic
|
Safety outputs
|
1 NC configurable
3 NO configurable
3 NO immediate
|
Safety inputs
|
2 positive safety input 24 V DC 8 mA
1 negative safety input
|
Maximum wire resistance
|
500 Ohm
|
Time delay range
|
0...900 s off delay
|
Input compatibility
|
Normally closed circuit conforming to ISO 14119
XC limit switch conforming to ISO 14119
Mechanical contact conforming to ISO 14119
Normally closed circuit conforming to ISO 13850
Antivalent pair conforming to ISO 14119
OSSD pair conforming to IEC 61496-1-2
3-wire proximity sensors PNP
|
[Ie] rated operational current
|
5 A AC-1 for normally open relay contact
3 A AC-15 for normally open relay contact
5 A DC-1 for normally open relay contact
3 A DC-13 for normally open relay contact
3 A AC-1 for normally closed relay contact
1 A AC-15 for normally closed relay contact
3 A DC-1 for normally closed relay contact
1 A DC-13 for normally closed relay contact
|
Control outputs
|
4 on/off configurable pulsed output
|
Input/output type
|
Semiconductor output 24 V DC, 20 mA Z2, not safety-related
Pulsed output for diagnostics 24 V DC, 20 mA Z1, not safety-related
|
[Ith] conventional free air thermal current
|
16 A
|
Associated fuse rating
|
10 A gG for NO relay output circuit conforming to IEC 60947-1
|
Minimum output current
|
20 mA for relay output
|
Minimum output voltage
|
24 V for relay output
|
Maximum response time on input open
|
20 ms
|
[Ui] rated insulation voltage
|
250 V (pollution degree 2) conforming to IEC 60947-1
|
[Uimp] rated impulse withstand voltage
|
4 kV overvoltage category II conforming to IEC 60947-1
|
Mounting support
|
35 mm symmetrical DIN rail
|
Depth
|
120 mm
|
Height
|
100 mm
|
Width
|
45 mm
|
Net weight
|
0.350 kg
|
Environment
Standards
|
IEC 60947-5-1
IEC 61508-1 functional safety standard
IEC 61508-2 functional safety standard
IEC 61508-3 functional safety standard
IEC 61508-4 functional safety standard
IEC 61508-5 functional safety standard
IEC 61508-6 functional safety standard
IEC 61508-7 functional safety standard
ISO 13849-1 functional safety standard
IEC 62061 functional safety standard
|
Product certifications
|
TÜV
cULus
|
IP degree of protection
|
IP54 (mounting area) conforming to IEC 60947-1
IP40 (housing) conforming to IEC 60947-1
IP20 (terminals) conforming to IEC 60947-1
|
Ambient air temperature for storage
|
-25…85 °C
|
Relative humidity
|
5…95 % non-condensing
|
Packing Units
Unit Type of Package 1
|
PCE
|
Number of Units in Package 1
|
1
|
Package 1 Height
|
6.500 cm
|
Package 1 Width
|
15.500 cm
|
Package 1 Length
|
13.500 cm
|
Package 1 Weight
|
440.000 g
|
Unit Type of Package 2
|
S03
|
Number of Units in Package 2
|
16
|
Package 2 Height
|
30.000 cm
|
Package 2 Width
|
30.000 cm
|
Package 2 Length
|
40.000 cm
|
Package 2 Weight
|
7.706 kg
|
Unit Type of Package 3
|
P06
|
Number of Units in Package 3
|
128
|
Package 3 Height
|
77.000 cm
|
Package 3 Width
|
60.000 cm
|
Package 3 Length
|
80.000 cm
|
Package 3 Weight
|
72.160 kg
|
Offer Sustainability
Sustainable offer status
|
Green Premium product
|
REACh Regulation
|
REACh Declaration
|
EU RoHS Directive
|
Pro-active compliance (Product out of EU RoHS legal scope)
|
Mercury free
|
Yes
|
RoHS exemption information
|
Yes
|
China RoHS Regulation
|
China RoHS declaration
|
Environmental Disclosure
|
Product Environmental Profile
|
Circularity Profile
|
End of Life Information
|
WEEE
|
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
|
California proposition 65
|
"WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov"
|
|
|